Spring Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: pass65

5V0-21.21 VMware HCI Master Specialist Questions and Answers

Questions 4

An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.

Why is this behavior being seen?

Options:

A.

vSAN network diagnostic mode is not enabled.

B.

vSAN proactive tests haven’t been run yet.

C.

vSAN performance service is turned off.

D.

vSAN performance verbose mode is not enabled.

Buy Now
Questions 5

A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.

What will be the impact on the vSAN cluster?

Options:

A.

There will be no impact on performance.

B.

The VMs will no longer be accessible.

C.

The performance will be degraded.

D.

The VMs will be in a suspended state.

Buy Now
Questions 6

An administrator is planning to deploy workloads on a six node vSAN cluster, and all nodes are distributed equally across three racks.

Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?

Options:

A.

Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (erasure coding).

B.

Add two additional hosts per rack, and configure vSAN with three fault domains and FTT=1.

C.

Add an additional host per rack, and configure vSAN with three fault domains and FTT=2.

D.

Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (mirroring).

Buy Now
Questions 7

During a vSAN design workshop, a customer expressed a requirement to decommission an existing enterprise NAS device that provides iSCSI services for a clustered application.

Based on the current state analysis, the following information was noted:

• Current utilization is 500 LUNs.

• All clustered workloads are configured for Multiple Connections per Session.

• LUN sizes range between 10 TB to 30 TB.

What should the architect state regarding the requirements?

Options:

A.

All requirements can be satisfied without any change.

B.

Only single connection per session is supported.

C.

The number of LUNs require additional licensing.

D.

It is a best practice to maintain a LUN size of 8 TB.

Buy Now
Questions 8

Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

Options:

A.

When a site is disconnected, the VM will lose access to its VMDK.

B.

When a site is disconnected, the VM will continue to have access to its VMDK.

C.

Bandwidth is unnecessarily sent across the inter-site link.

D.

Proper policies result in higher inter-site bandwidth utilization.

Buy Now
Questions 9

Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.

The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.

The current vSAN cluster has the following configuration:

* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM

* 1 Disk Group per vSAN node

- 1 x 400 GB

- 4 x 1.8 TB

* De-duplication and Compression is enabled.

* vSAN Capacity is currently:

- Total: 72 TB

- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).

As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.

Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

Options:

A.

Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.

B.

Update the existing Disk Group, and claim the newly installed drives for each node.

C.

Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.

D.

Install an additional 3 x 1.8 TB SSDs per vSAN node.

E.

Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.

Buy Now
Questions 10

* Highest possible mitigation during a host failure in terms of capacity.

* A constraint in this year’s IT budget.

What should the architect recommend?

Options:

A.

Enable operations reserve.

A minimum cluster of 3 vSAN nodes.

B.

Enable host build reserve.

A minimum cluster of 4 vSAN nodes.

C.

Enable performance services.

A minimum cluster of 6 vSAN nodes.

D.

Enable IOInsight Metrics.

A minimum cluster of 2 vSAN ROBO nodes.

Buy Now
Questions 11

An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the “Full-data migration” option.

What will happen after this action is taken?

Options:

A.

The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.

B.

The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.

C.

The host will enter in maintenance mode and only data with no redundancy will remain accessible.

D.

The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.

Buy Now
Questions 12

An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:

* Maximize the vSAN datastore usable capacity.

* Deduplication and compression are required to help utilize available capacity efficiency.

* Ensure the highest level of resiliency wherever possible.

Which disk group configuration should the architect include in the design?

Options:

A.

One disk group per host, with one cache tier flash disk and four capacity tier flash disks.

B.

Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.

C.

Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.

D.

Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.

Buy Now
Questions 13

A cache disk failure marked a vSAN disk group as failed, and the data is being rebuilt on other disk groups.

Which action should the vSAN administrator take to reduce the negative impact on the VMs?

Options:

A.

Enabling Resync Throttling

B.

Enabling Maintenance mode with no data evacuation

C.

Enabling automatic rebalance

D.

Setting the vSAN policy’s IOPS limit for object value to 0 (unlimited)

Buy Now
Questions 14

After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).

Which step should be taken to resolve this issue?

Options:

A.

Configure vmk0 with IP address on the same range as that of vmk1.

B.

Tag the vmk0 for vSAN traffic.

C.

Configure vmk1 with IP address on the different network than that of vmk0.

D.

Tag the vmk1 for Witness traffic.

Buy Now
Questions 15

An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.

The company also has the following:

* An iSCSI array of 300TB. which runs at 76% of its capacity

* A NAS system of 200TB, which runs at 10% of its capacity

* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity

The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.

Which storage option will work for this use case?

Options:

A.

Create an HCI Mesh using the first cluster’s datastore.

B.

Obtain additional free capacity from the existing NAS storage.

C.

Obtain additional free capacity from the existing FC storage.

D.

Create an HCI Mesh using the second cluster’s datastore.

Buy Now
Questions 16

An administrator notes that the Data-At-Rest Encryption keys have expired.

Which action is needed to resolve this situation?

Options:

A.

Add a new Standard Key Provider at the vSAN cluster level

B.

Generate new encryptions keys at the vSAN cluster level

C.

Add an additional KMS at the vCenter server level

D.

Generate new encryptions keys at the vCenter server level

Buy Now
Questions 17

Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this message displayed:

The increase in latency in the vSAN stack might be beyond expected limits.

Which two root causes can be identified to help remediate the issue? (Choose two.)

Options:

A.

vSAN VMKemel portgroup is configured with the “Route based on IP hash” teaming policy

B.

vSAN encryption is enabled

C.

Large packet losses and retransmissions on the network layer

D.

Incorrect sizing of the disk groups capacity disks

E.

One or more disk groups are congested

Buy Now
Questions 18

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.

Which three prerequisites must be satisfied before completing the task? (Choose three.)

Options:

A.

Create an encryption storage policy

B.

Enable Data-In-Transit encryption first

C.

Enable that the virtual machines are powered on

D.

Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E.

Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F.

Establish a trusted connection with the KMS

Buy Now
Questions 19

A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.

Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

Options:

A.

Place the host in maintenance mode with Ensure Accessibility

B.

Disconnect from vCenter Server

C.

Place the host in maintenance mode with Full Data migration

D.

Place the host in maintenance mode with no data migration

E.

Remove from vSAN cluster

F.

Delete the disk group(s) on the legacy host

Buy Now
Exam Code: 5V0-21.21
Exam Name: VMware HCI Master Specialist
Last Update: May 7, 2026
Questions: 66

PDF + Testing Engine

$63.52  $181.49

Testing Engine

$50.57  $144.49
buy now 5V0-21.21 testing engine

PDF (Q&A)

$43.57  $124.49
buy now 5V0-21.21 pdf