At Marks4sure, we are dedicated to providing IT professionals with the most accurate and reliable preparation materials for the International Code Council 93-Tall-Mass-Timber-Buildings exam. To support your certification journey, we have made a selection of our premium 2026 Special Inspector practice questions and answers available completely free. You can take this practice test as many times as you need. Every question includes a detailed, expertly verified explanation to ensure you fully grasp the core security concepts before test day.
Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, the 2x2 block is intended for what purpose according to AWC Technical Report 10?
Refer to the figure by clicking on the EXHIBIT button above.


The exterior wall section shown in the Figure provides the prescribed noncombustible protection required by which Construction Type?
Refer to the exhibit by clicking on the EXHIBIT button above.

Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.
The bearing area between the CLT and glulam is the minimum required.
What are the minimum dimensions, in inches, for the wood block shown in red?
Refer to the figure by clicking on the EXHIBIT button above.


The exterior wall section shown in the Figure provides the prescribed noncombustible protection required by which Construction Type?
What fire-resistance rating is required for Type IV-C exterior and interior bearing walls?
Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.
Which of the following is an acceptable alternative for protecting structural connections from fire in Type IV-A, IV-B or IV-C construction?
What fire-resistance rating is required for floors in Type IV-A, IV-B and IV-C construction?
Regarding water supply for the protection of buildings under construction, when combustible building materials of the building under construction are delivered to a site, the minimum fire flow provided shall be _____ gpm.
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
The building owner shall be responsible for each of the following for fire safety during construction except:
Which of the following construction Types permit concealed spaces to be protected by completely filling the concealed space with noncombustible insulation?
Refer to the figure by clicking on the EXHIBIT button above.


In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?
Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown and according to AWC Technical Report 10, what is the time assigned in minutes to 5/8 in. Type X gypsum board for connection fire protection thermal separation requirements?
Given: Sealants or adhesives need not be provided where they are not a required component of a tested fire resistance rated assembly.
If a sealant is required, it must meet the requirement of ASTM:
In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:
Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?
Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?
Refer to the exhibit by clicking on the EXHIBIT button above.


In the detail shown, which fasteners require fire protection according to AWC Technical Report 10?