At Marks4sure, we are dedicated to providing IT professionals with the most accurate and reliable preparation materials for the International Code Council 93-Tall-Mass-Timber-Buildings exam. To support your certification journey, we have made a selection of our premium 2026 Special Inspector practice questions and answers available completely free. You can take this practice test as many times as you need. Every question includes a detailed, expertly verified explanation to ensure you fully grasp the core security concepts before test day.

Questions 4

Refer to the exhibit by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 4

In the detail shown, the 2x2 block is intended for what purpose according to AWC Technical Report 10?

Options:

A.

Decorative trim

B.

Provide 1-hour of fire protection for the steel ledger

C.

Resist the passage of air at abutting edges of wood members

D.

Protect the abutting wood edges from char contraction

Buy Now
Questions 5

Refer to the figure by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 5

93-Tall-Mass-Timber-Buildings Question 5

The exterior wall section shown in the Figure provides the prescribed noncombustible protection required by which Construction Type?

Options:

A.

Type IV-A

B.

Type IV-B

C.

Type IV-C

D.

Type IV-HT

Buy Now
Questions 6

Refer to the exhibit by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 6

Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.

The bearing area between the CLT and glulam is the minimum required.

What are the minimum dimensions, in inches, for the wood block shown in red?

Options:

A.

1.5 x 1.5

B.

2 x 2

C.

3 x 3

D.

4 x 4

Buy Now
Questions 7

Refer to the figure by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 7

93-Tall-Mass-Timber-Buildings Question 7

The exterior wall section shown in the Figure provides the prescribed noncombustible protection required by which Construction Type?

Options:

A.

Type IV-A

B.

Type IV-B

C.

Type IV-C

D.

Type IV-HT

Buy Now
Questions 8

What fire-resistance rating is required for Type IV-C exterior and interior bearing walls?

Options:

A.

1 hour

B.

2 hours

C.

3 hours

D.

4 hours

Buy Now
Questions 9

Refer to the exhibit by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 9

In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.

Options:

A.

1.5

B.

1.75

C.

2

D.

3

Buy Now
Questions 10

Which of the following is an acceptable alternative for protecting structural connections from fire in Type IV-A, IV-B or IV-C construction?

Options:

A.

Testing of connections in accordance with ASTM E136

B.

Limiting connections to those incorporating wood-on-wood bearing

C.

Using connectors that are rated by the manufacturer for fire performance

D.

Engineering analysis showing limited temperature rise at the connector for the required fire-resistance time of connected members

Buy Now
Questions 11

What fire-resistance rating is required for floors in Type IV-A, IV-B and IV-C construction?

Options:

A.

1 hour

B.

2 hours

C.

3 hours

D.

4 hours

Buy Now
Questions 12

Regarding water supply for the protection of buildings under construction, when combustible building materials of the building under construction are delivered to a site, the minimum fire flow provided shall be _____ gpm.

Options:

A.

100

B.

200

C.

500

D.

750

Buy Now
Questions 13

In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:

Options:

A.

mineral wool.

B.

one-half-inch gypsum board.

C.

7/16-inch wood structural panels.

D.

mass timber complying with IBC Section 2304.11.

Buy Now
Questions 14

The building owner shall be responsible for each of the following for fire safety during construction except:

Options:

A.

completion of a daily fire safety inspection at the project site by the site safety director.

B.

documentation and maintenance on-site of each inspection’s results until a certificate of occupancy has been issued.

C.

securing documentation in a fire- and water-resistant safe until a certificate of occupancy has been issued.

D.

making documentation immediately available on-site for presentation to the fire code official upon request.

Buy Now
Questions 15

Which of the following construction Types permit concealed spaces to be protected by completely filling the concealed space with noncombustible insulation?

Options:

A.

Type IV-A

B.

Type IV-B

C.

Type IV-C

D.

Type IV-HT

Buy Now
Questions 16

Refer to the figure by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 16

93-Tall-Mass-Timber-Buildings Question 16

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.

15%

B.

20%

C.

30%

D.

40%

Buy Now
Questions 17

Which of the following is the best definition of Type IV-B construction?

Options:

A.

100% noncombustible protection on all mass timber surfaces

B.

50% noncombustible protection on the exterior and interior mass timber elements

C.

100% exposed mass timber except: shafts, concealed spaces, and outside of exterior walls

D.

Noncombustible protection on all surfaces of mass timber except for limited exposed mass timber elements

Buy Now
Questions 18

Refer to the exhibit by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 18

In the detail shown and according to AWC Technical Report 10, what is the time assigned in minutes to 5/8 in. Type X gypsum board for connection fire protection thermal separation requirements?

Options:

A.

Both layers = 20

B.

Both layers = 40

C.

Layer adjacent to the connection = 20 and second layer = 40

D.

Layer adjacent to the connection = 40 and second layer = 20

Buy Now
Questions 19

Given: Sealants or adhesives need not be provided where they are not a required component of a tested fire resistance rated assembly.

If a sealant is required, it must meet the requirement of ASTM:

Options:

A.

E114

B.

E119

C.

C920

D.

D3498

Buy Now
Questions 20

In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:

Options:

A.

1 hour

B.

1-1/2 hours

C.

2 hours

D.

3 hours

Buy Now
Questions 21

Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?

Options:

A.

Standpipes shall be provided in accordance with IFC Section 3313.

B.

The IFC specifically requires a portable water supply.

C.

Required exterior wall coverings on all floor levels more than 2 levels below the floor under construction, including mezzanines.

D.

At least two layers of noncombustible protection, where noncombustible protection is required for the building element, on all mass timber more than 4 stories below the uppermost floor under construction.

Buy Now
Questions 22

Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

Options:

A.

Type IV-A construction requires at least 80 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

B.

Type IV-B construction requires at least 40 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

C.

Type IV-C construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

D.

Type IV-HT construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

Buy Now
Questions 23

Which of the following requires continuous special inspection?

Options:

A.

Bolted connections

B.

Concealed connections

C.

Anchorage of mass timber construction to deep foundation systems

D.

Adhesive anchors installed horizontally resisting sustained tension loads

Buy Now
Questions 24

Refer to the exhibit by clicking on the EXHIBIT button above.

93-Tall-Mass-Timber-Buildings Question 24

93-Tall-Mass-Timber-Buildings Question 24

In the detail shown, which fasteners require fire protection according to AWC Technical Report 10?

Options:

A.

Those in the 2x2 block

B.

Those in the 2x10s

C.

Those in the gypsum filler

D.

The 1/2 in. lag screws attaching the steel ledger

Buy Now