According to IEEE C57.12.00, a durable, metal, name plate shall be affixed to each transformer by the:

Options:

A.

manufacturer.

B.

owner.

C.

purchaser.

D.

QA/QC Inspector.

Buy Now
Questions 5

What requirement shall be included in a lockout/tagout procedure?

Options:

A.

An arc flash requirement where a high level of exposure is foreseen

B.

A power testing requirement where a direct exposure situation can be detected

C.

A voltage testing requirement where there might be direct exposure to electrical hazards

D.

A voltage and current testing for direct exposure situations

Buy Now
Questions 6

During the course of manufacturing the supplier/vendor may propose design changes that could impact cost, schedule and/or quality. In such cases, the source inspector should:

Options:

A.

prepare a summary of the changes made for inclusion in their report and subsequent action by the purchaser.

B.

request that the supplier/vendor develop a cost/benefit analysis for review and approval by the inspector.

C.

prepare a cost/benefit analysis in order to justify their acceptance or rejection of the proposed changes.

D.

request that the supplier/vendor propose such changes in writing for review by the purchaser.

Buy Now
Questions 7

A qualified person, as defined by NFPA 70E, is a person:

Options:

A.

designated by the authority having jurisdiction as an electrician, electrical technician, electrical supervisor or electrical engineer.

B.

who has taken the national electrical safety certification and received the certificate.

C.

with a 2 year associate degree in electrical technology or electrical engineer or the IBEW equivalent.

D.

who has demonstrated skills related to the operation of electrical equipment and received safety training to identify and avoid the hazards.

Buy Now
Questions 8

What is the purpose of an equipment risk assessment in the source inspection process?

Options:

A.

To identify the level of risk associated with failure of the supplier/vendor’s quality system

B.

To identify the level of effort for source inspection activities during the manufacture/fabrication phase of a project at the supplier/vendor facility

C.

To identify which shops will be able to bid on certain types of equipment i.e. to identify the shops that can supply equipment critical to project success

D.

To determine the level of business insurance required in the event the supplier/vendor is unable to deliver the product on time while meeting contractual agreements

Buy Now
Questions 9

What document provides information on design and installation of electrical systems for fixed and floating offshore petroleum facilities for unclassified and Class I, Zone 0, Zone 1 and Zone 2 locations?

Options:

A.

NFPA 70

B.

IEEE 841

C.

API RP 14F

D.

API RP 14FZ

Buy Now
Questions 10

In a Class I hazardous area, what is the maximum distance from an enclosure, containing arcing devices should a conduit seal be located?

Options:

A.

4 inches 10.16 cm away from the closest union or coupling

B.

10 inches 25.4 cm

C.

12 inches 30.48 cm

D.

18 inches 45.72 cm

Buy Now
Questions 11

Inspections, examinations, and tests must be performed in accordance with the source Inspection Test Plan, project specification, applicable codes and standards and meet:

Options:

A.

published catalog data.

B.

manufacturer's standard.

C.

the applicable acceptance criteria.

D.

commonly accepted industry practice.

Buy Now
Questions 12

According to API 541, determination of efficiency and power, locked-rotor current, power factor, torque, full-load current and slip are some of the tests verified when performing a:

Options:

A.

complete test.

B.

compliance test.

C.

design test.

D.

routine test.

Buy Now
Questions 13

The cosine of the difference in phase angle between voltage and current is:

Options:

A.

power factor.

B.

real power.

C.

apparent power.

D.

mho.

Buy Now
Questions 14

According to NFPA 70, installed conductor insulation temperature rating shall be a required marking on what type of system?

Options:

A.

Metallic busways

B.

Nonmetallic auxiliary gutters

C.

Sheet metallic auxiliary gutters

D.

Non-metallic busways

Buy Now
Questions 15

What is an insulation resistance test?

Options:

A.

A test that determines the adequacy of electrical insulation for the normally occurring over voltage transient

B.

A test that determines the corrosive contaminants around the conductors, terminal spacing problems, and tolerance errors in cables

C.

A spot overvoltage test which uses an applied DC voltage to measure ohms

D.

A test that determines the voltage that electrical insulation can withstand during normal operation

Buy Now
Questions 16

Final inspection and shipping preparations of switchgear typically consists of verifying all of the following except:

Options:

A.

all final manufacturing and drawing issues are closed.

B.

correct engraving of unit and master nameplates.

C.

visual inspection of packaging requirements.

D.

all items on the manufacturer's QC checkout are signed off.

Buy Now
Questions 17

Which information should be included at a minimum in a source inspection report?

Options:

A.

Inspector’s travel reimbursement total

B.

Reference drawings/data used, including drawing numbers

C.

Supplier profit margin

D.

Internal purchaser budget code only

Buy Now
Questions 18

What is the purpose of labeling the temperature range on electrical equipment used in a Class I hazardous area?

Options:

A.

To verify the process temperature and the equipment temperature have the same Class I rating

B.

To ensure that the equipment maximum temperature does not exceed the autoignition temperature of the specific gas or vapor to be encountered

C.

To ensure the equipment is compatible with the other Class I devices

D.

To verify the maximum process temperature does not exceed high levels

Buy Now
Questions 19

Which document should identify the inspection activities to be performed by the assigned source inspector and include the applicable acceptance criteria?

Options:

A.

Purchase requisition

B.

Inspection and Test Plan (ITP)

C.

Shipping release form

D.

Supplier observation report

Buy Now
Questions 20

During switchgear source inspection, which item must be verified to prevent opening a medium-voltage door when the isolation switch handle is in the full ON position?

Options:

A.

Space heater thermostat

B.

Door interlock operation

C.

Meter accuracy class

D.

CT polarity marking

Buy Now
Questions 21

According to API 541, the combined runout for areas on the shaft that are to be observed by radial vibration probes shall not exceed:

Options:

A.

the maximum vibration amplitude specified in the manufacturer's test criteria.

B.

12.7 µm 0.5 mils.

C.

10% of allowed unfiltered peak to peak vibration amplitude or 3.2 µm 0.125 mils, whichever is greater.

D.

25% of allowed unfiltered peak to peak vibration amplitude or 6.4 µm 0.25 mils, whichever is greater.

Buy Now
Questions 22

Which of the following is listed as a typical transformer inspection point in the guide?

Options:

A.

Verification of PCB content labeling

B.

Rotor bar balance check

C.

Impeller alignment

D.

Ventilation fan blade pitch adjustment

Buy Now
Questions 23

According to the referenced API standard in the guide, special purpose induction motors covered by API STD 541 are:

Options:

A.

100 hp and larger

B.

250 hp and larger

C.

375 kW (500 hp) and larger

D.

1000 kW and larger only

Buy Now
Questions 24

According to API 541, when shall the vendor provide calculated data from the final witness testing?

Options:

A.

Two weeks following testing

B.

Upon request

C.

At time of final shipment

D.

Immediately upon completion of testing

Buy Now
Questions 25

Each source inspection assignment should have a detailed Inspection and Test Plan ITP which identifies the:

Options:

A.

day the inspection is to start.

B.

individuals involved in the inspection.

C.

activities to be performed during the inspection.

D.

activities to be performed and the acceptance criteria.

Buy Now
Questions 26

What standard is used for the installation of signaling and communications conductors, equipment, and raceways?

Options:

A.

IEC 20047

B.

NEMA 250

C.

NFPA 70

D.

IEEE C37.20.2

Buy Now
Questions 27

According to API 541, subsequent to completion of manufacture and testing, the vendor shall revise and resubmit the previously supplied purchase data including all the following except:

Options:

A.

rotor-balance report.

B.

operating manual.

C.

as-built data sheet.

D.

shop test data.

Buy Now
Questions 28

What method is used to verify tightness of accessible bolted electrical connections?

Options:

A.

Compression of the lock-nut

B.

Visual inspection of torque markings

C.

Verification of assembly check sheet

D.

Calibrated torque wrench

Buy Now
Questions 29

The highest voltage rating on a piece of medium voltage equipment is the:

Options:

A.

basic impulse level.

B.

AC high potential.

C.

DC high potential.

D.

nominal voltage.

Buy Now
Questions 30

Deviations from specifications must be approved by the:

Options:

A.

manufacturer's engineer.

B.

vendor's quality manager.

C.

inspection coordinator.

D.

responsible engineer.

Buy Now
Questions 31

According to NFPA 70, is the use of Teflon tape on threaded connections for conduits allowed?

Options:

A.

Only when installed in a Class I, Division 2 area

B.

Yes, the use of Teflon on metal raceways, cable armor, and other metal enclosures prevents water from entering

C.

No, metal raceways and other metal enclosures for conductors shall be metallically joined together into a continuous electrical conductor

D.

Yes, the use of Teflon ensures an explosion proof vapor seal

Buy Now
Questions 32

According to API 541, totally enclosed machines TEFC, TEPV, TEWAC, and TEAAC are equipped with which of the following?

Options:

A.

Low-point drain

B.

Heat exchanger cooling fan

C.

Bearing RTDs

D.

Surge protectors

Buy Now
Questions 33

Which referenced standard in the guide applies to metal-enclosed low-voltage power circuit breaker switchgear?

Options:

A.

ANSI/IEEE C57.12.00

B.

ANSI/IEEE C37.20.1

C.

API RP 14FZ

D.

NEMA 250 only