CDCP Certified Data Centre Professional (CDCP) Questions and Answers

Questions 4

Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?

Options:

A.

Class A

B.

Class B

C.

Class D

D.

Class K

Buy Now
Questions 5

What should be considered when using a direct air handler for a data centre?

Options:

A.

Cost of operation as power consumption on these units tend to be higher compared to traditional air conditioning technology.

B.

Temperature, humidity and contamination of the outdoor environment.

C.

Space available inside the computer rooms as the air handler space requirement for the inside the Computer room is quite large.

D.

The availability of three-phase power due to the high power requirements of these air handler units.

Buy Now
Questions 6

The three elements of the fire triangle are,and. (Choose three.)

Options:

A.

Oxygen

B.

Earth

C.

Heat

D.

Water

E.

Fuel

Buy Now
Questions 7

What is the effect of a high relative humidity in the data centre?

Options:

A.

There is a risk of electrostatic discharge.

B.

In a data centre environment relative humidity is not important, only temperature matters.

C.

There is a risk of not properly functioning of the smoke detectors.

D.

There is a risk of corrosion.

Buy Now
Questions 8

What needs to be installed in the battery room when using Lithium-ion batteries?

Options:

A.

A battery management system to monitor and prevent unsafe temperatures during charging/discharging.

B.

High capacity air-conditioning equipment since Lithium-ion batteries are sensitive to high temperatures, which can reduce their lifetime.

C.

A proper ventilation system since Lithium-ion batteries produce highly flammable Hydrogen gas during charging.

D.

A proper supply of distilled water.

Buy Now
Questions 9

What is the most cost-effective way to avoid EMF issues within the Computer room?

Options:

A.

Create a distance between the EMF source and the ICT equipment / copper network cabling

B.

Install TUVapp'oved shielding material

C.

Reducing the voltage in the computer room

D.

Reducing the temperature in computer room to 18° C / 64= Fahrenheit

Buy Now
Questions 10

Which type of copper wire is used for grounding the racks to the SRG?

Options:

A.

Thin copper cable to keep the cost low for grounding.

B.

Thick copper cable to create better grounding.

C.

Braided copper wire or flat copper strip.

D.

Copper cable with plastic insulation (isolation).

Buy Now
Questions 11

What factor should be considered when placing fluorescent lighting in the data centre?

Options:

A.

Fluorescent lights should not be connected to the back-up generator.

B.

Fluorescent lights should only be installed in equipment supporting areas and not in the Computer/Server room.

C.

Fluorescent lights should not be connected to the mains power supply.

D.

Fluorescent lights should not be connected to the same UPS that supports the ICT equipment.

Buy Now
Questions 12

Which one of the following is an example of Direct Cost?

Options:

A.

Legal fees

B.

Damaged brand perception

C.

Negative public relations

D.

Reduced customer satisfaction

Buy Now
Questions 13

Which one of the following represents the three elements (oxygen, heat and fuel) to interact in order for the fire to exist?

Options:

A.

The Fire Hexagon

B.

The Fire Class

C.

The Fire Triangle

D.

The Fire Technology

Buy Now
Questions 14

Which source is used in fiber cable to transmit data?

Options:

A.

Signals

B.

Electric

C.

Light

D.

Pulse

Buy Now
Questions 15

New server equipment is arriving at your data centre, where should it be tested?

Options:

A.

In the Holding area

B.

In the Computer! Server room

C.

In the Media storage area

D.

In the Staging room

Buy Now
Questions 16

Which Class of Fires involves cooking appliances?

Options:

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Buy Now
Questions 17

What is the primary reason to install a monitoring system in the data centre?

Options:

A.

To notice abnormalities early so that actions can be taken to avoid disasters

B.

To create a proper asset database

C.

To implement automated change management

D.

To be able to collect data for capacity planning

Buy Now
Questions 18

What is the purpose of a service corridor?

Options:

A.

To create a secure and conditioned environment where media can be stored in a controlled manner.

B.

It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.

C.

It provides a safe, vented and secure area where standby generators can operate safely.

D.

It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.

Buy Now
Questions 19

Which type of Fire Detection Device is recommended for protecting a Data Center?

Options:

A.

Heat detector

B.

Smoke detector

C.

Flame detector

D.

None of the above

Buy Now
Questions 20

What is the main risk for a data centre when the water supply fails?

Options:

A.

Failure to the water supply could result in IT failure and/or denial of access to operate.

B.

Failure to the water supply could result in DX cooling systems to fail.

C.

Failure to the water supply could cause issues for the cooling of back-up generators.

D.

Failure to the water supply could result in sudden changes of the relative humidity in the Computer room.

Buy Now
Questions 21

What is the recommended location for the Isolation Transformer in relation to the ICT-Equipment location?

Options:

A.

The isolation transformer should be as close as possible to the ICT equipment but taking into account potential EMF.

B.

The isolation transformer should be as far away as possible to the ICT equipment to avoid potential EMF.

C.

The isolation transformer has to be installed within the power entry point of the building due to electrical code (regulation) requirements.

D.

The isolation transformer should be installed within the rack in which the ICT equipment has been installed.

Buy Now
Questions 22

Which one of the following is an example of Indirect Cost?

Options:

A.

Legal fees

B.

Damaged brand perception

C.

System recovery

D.

Cost revenues

Buy Now
Questions 23

Which one of the following is an Audible Signaling and Notification Device?

Options:

A.

Sirens

B.

Strobes

C.

Alarms

D.

Clocks

Buy Now
Questions 24

Does unplanned downtime of a data centre have an impact on the business results?

Options:

A.

No, because data centres operate independently from the business.

B.

No, unplanned data centre downtime is already financially planned for in the yearly budget planning process.

C.

Yes, data centre downtime can result in business downtime.

D.

Yes, but data centre downtime only impacts the airline industry.

Buy Now
Questions 25

Which design consideration should be implemented with an Inergen-based fire suppression system?

Options:

A.

Install protective covers around the nozzles to avoid accidental gas dumps.

B.

Install the gas containers (tanks) close to the data centre.

C.

To use Inergen only for fires which are not related to electrical power.

D.

Pressure relief valves are required in the room that needs protection.

Buy Now
Questions 26

Mean time between failures is best considered a measure of:

Options:

A.

Size

B.

Cost

C.

Duration

D.

Reliability

Buy Now