CFI-I Certified Fire Inspector I (CFI-1) Questions and Answers
What class of organic peroxide burns rapidly and presents a moderate reactivity hazard?
What is the maximum volume of Class I, Class II, and Class III A liquids allowed to be stored in an individual storage cabinet?
Labels for individual containers, cartons, or packages of hazardous materials require which of the following?
How much clear space shall be maintained around the circumference of a fire hydrant (except as otherwise required or approved)?
The following types of systems are addressed within the scope of NFPA 25, Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems EXCEPT
Which of the following statements regarding equivalencies is correct?
I. Equivalencies may result in the provision of less protection than the applicable code requirements with the approval of the AHJ.
II. Buildings with alternate fire protection features that are approved by the AHJ are considered to be in compliance with the fire code.
III. Applications for consideration of an alternate fire protection feature must be accompanied by the documentation necessary to support the request.
What is a system that discharges water from open sprinklers activated by a detection system called?
When conducting a main drain test of a water-based fire protection system riser, what percentage of reduction in full flow pressure (as compared to the acceptance test or previously performed test) will trigger an investigation into the cause of the reduction?
In a low hazard occupancy, what is the maximum allowable travel distance to a Class A portable fire extinguisher?
What is the minimum acceptable flow at the base of the riser for a pipe-schedule sprinkler system in an ordinary hazard (Group 1) occupancy?
While conducting an inspection, a fire inspector observes a hazardous condition that presents an imminent danger to the occupants of the building being inspected. What action should the inspector take?
Emergency shutoff valves and internal valves that are fitted for remote closure for LP-Gas vehicle fuel dispensing shall be tested for proper operation at what interval?
Which of the following may initiate a fire alarm system?
I. A manual fire alarm
II. An automatic detector
III. An extinguishing system
The NFPA Standard for the installation of stationary pumps for fire protection is:
How often must a hose valve on a hose station attached to a sprinkler system and Class II standpipe system be tested?
Sprinkler systems in garages that are used only for the parking of vehicles shall be designed for which of the following hazard classifications?
Spray undercoating or spray body lining of vehicles shall be conducted a minimum of what distance from open flames or spark-producing equipment?
Fire extinguishers having a gross weight not exceeding 40 lb (18.14 kg) shall be installed to which of the following criteria?
What is the minimum static pressure drop required when flow testing fire hydrants?
What is the color of a heat-sensing fire detector with a temperature classification of extra high?
Prior to seeking system acceptance for a sprinkler installation, an installer shall do which of the following?
I. Perform all required acceptance tests
II. Complete all contractors’ material and test certificates
III. Notify the AHJ of the time and date of the test
IV. Complete owners' approval form and forward it to the AHJ
How often shall emergency egress and relocation drills in educational occupancies be conducted?
Records regarding fire prevention inspections must include all of the following EXCEPT
Guard posts protecting hazardous material use, dispensing, or storage areas from vehicles must be a minimum of how many feet (meters) from the tank?