Spring Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: pass65

DES-1721 Specialist - Implementation Engineer SC Series Exam Questions and Answers

Questions 4

What is the name of the out-of-band system management connection for SC9000 systems?

Options:

A.

iDRAC

B.

MMC

C.

IPMI

D.

iLo

Buy Now
Questions 5

A customer has a volume that was created with the wrong datapage size. What is the simplest and least disruptive method to change this volume’s page size?

Options:

A.

Copy the volume, then mount the new volume

B.

Mirror the volume, then mount the mirrored volume

C.

Mirror the volume, then migrate to mirror

D.

Migrate the volume, then delete the source volume

Buy Now
Questions 6

Based on the exhibit, a customer is using a Virtual Port Mode configuration. If the cable for Domain 1 on Controller 1 is disconnected during failover testing, will the SC Series array port failover work?

DES-1721 Question 6

Options:

A.

No, the configuration contains only a single port per domain and will not provide port failover.

B.

Yes, the configuration will provide port failover as the system is configured for Virtual Port Mode.

C.

No, port failover only works in Legacy Port Mode.

D.

Yes, the configuration will provide port failover regardless of domains or mode.

Buy Now
Questions 7

Which redundancy option is available for drives on an SC7020 storage array?

Options:

A.

Dual redundancy is the default for all drives

B.

Single redundancy is the default for all drives

C.

Single or dual redundancy for 1.8 TB up to 3.9 TB drives

D.

Single or dual redundancy for 4 TB and higher drives

Buy Now
Questions 8

How many SC400 enclosures can be supported by an SC7020 controller?

Options:

A.

8

B.

10

C.

12

D.

16

Buy Now
Questions 9

Refer to the exhibit.

DES-1721 Question 9

When scanning Fibre Channel on a QLogic HBA what information can be obtained?

Options:

A.

The volume mapped to the QLogic HBA

B.

WWN of the QLogic HBA

C.

WWN of the connected Storage Center

D.

WWN of the SAN switch

Buy Now
Questions 10

You recently deployed two SC9000 storage arrays at a customer site one week ago and verified that everything was working correctly with replication. However, the customer notifies you that every time they tested disaster recovery (DR), they lost access to the volumes when the DR array shut down.

Why did the volumes become inaccessible during testing?

Options:

A.

Asynchronous Replication with Deduplication

B.

High Consistency Synchronous Replication

C.

Asynchronous Replication with Active Replay

D.

High Availability Synchronous Replication

Buy Now
Questions 11

A customer wants to configure a threshold alert definition. Which types of definitions can be configured?

Options:

A.

Latency, Disks, and Replication

B.

Storage, Latency, and Disks

C.

Storage, Replication, and Hardware

D.

I/O Usage, Storage, and Replication

Buy Now
Questions 12

What information is required to configure an iSCSI initiator?

Options:

A.

Alias, Zone, Zone Config name

B.

Target IP Address, subnet, gateway

C.

VLAN tag, port speed, Multicast control setting

D.

MAC address, VLAN broadcast address

Buy Now
Questions 13

What does Compression use to reduce data space?

Options:

A.

Ocarina’s proprietary Algorithm

B.

Duplicate page identification

C.

On Demand Data Progression

D.

Audit cycles

Buy Now
Questions 14

Which SC Series licenses are applied at the factory?

Options:

A.

SC4020 and SC7020

B.

SC7020 and SCv2000

C.

SC8000 and SC9000

D.

SCv2000 and SC8000

Buy Now
Questions 15

Refer to the exhibits.

Which is the correct front end and cabling for an SC7020 with 2 port FC connectivity?

A)

DES-1721 Question 15

B)

DES-1721 Question 15

C)

DES-1721 Question 15

D)

DES-1721 Question 15

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Buy Now
Questions 16

What is the correct system hierarchy of SC Series array storage virtualization?

DES-1721 Question 16

Options:

Buy Now
Questions 17

During the addition of an SCv360 enclosure to a SCv3020 the PCle SAS card is used for connectivity. The enclosure is NOT recognized by the system, why?

Options:

A.

SCv3020 does not allow enclosure expansion

B.

SCv2360 is unsupported for enclosure expansion

C.

SCv3020 does not support 12Gb SAS

D.

PCle SAS is unsupported for enclosure expansion

Buy Now
Questions 18

Which zones accurately describe the zoning requirement for replication connectivity to be established when the source array is in Legacy Port Mode and the target array is in Virtual Port Mode?

Options:

A.

Zone 1 = All Source Virtual Port WWNs + All Remote Physical Port WWNsZone 2 = All Source Physical Port WWNs + All Remote Virtual Port WWNs

B.

Zone 1 = All Physical WWNs from both arraysZone 2 = All Virtual WWNs from both arrays

C.

Zone 1 = All Source WWNs + All Remote Virtual Port WWNsZone 2 = All Source WWNs + All Remote Physical Port WWNs

D.

Zone 1 = All Source Virtual Port WWNs + All Remote Port WWNsZone 2 = All Source Physical Port WWNs + All Remote Port WWNs

Buy Now
Questions 19

Match the Snapshot type with the description related to Snapshot creation.

DES-1721 Question 19

Options:

Buy Now
Questions 20

A customer is using an SC9000 array with two chained SC280 expansion enclosures. They need to expand its capacity by adding a third SC280 drive bay. What is the most cost efficient way to expand the array ' s capacity using as few chains as possible?

Options:

A.

Add the SC280 to the same chain as the existing SC280 enclosures

B.

Install two new SAS I/O cards and distribute the SC280 enclosures between them

C.

Add the new SC280 to a new chain on the same SAS I/O card

D.

Install a new SAS I/O card to connect the SC280 enclosure

Buy Now
Questions 21

A company is using an SC4020 array and the storage administrator wants to expand the available capacity by adding 92, 3.5” disk drives. Which expansion enclosure(s) can be used to meet the demand?

Options:

A.

1x SC280 drive bay

B.

2x SC180 drive bays

C.

4x SC220 drive bays

D.

8x SC200 drive bays

Buy Now
Questions 22

When you enable Storage Profiles on a SC with two tiers of flash drives, which storage profile will appear in addition to the standard storage profiles?

Options:

A.

High Priority

B.

Recommended

C.

Medium Priority

D.

Low Priority with Progression

Buy Now
Questions 23

Which component of the Dell Storage Manager (DSM) suite’s only purpose is to perform disaster recovery if the primary data collector is no longer available?

Options:

A.

Dell Storage Manager Client

B.

Dell Storage Manager Server Agent

C.

Dell Storage Manager Remote Data Collector

D.

Dell Application Protection Manager

Buy Now
Questions 24

A customer notices a volume is using an above average amount of Tier 1 RAID 10 space. What can be done to force this data into a lower RAID set/Tier?

Options:

A.

Stop I/O to the volume

B.

Change the storage profile of the volume

C.

Take a manual snapshot

D.

Move data to a different volume

Buy Now
Questions 25

What is the maximum number of drives per chain supported by an SC9000 storage array?

Options:

A.

168

B.

192

C.

512

D.

1024

Buy Now
Questions 26

What is order of steps that the Storage Center will follow when it senses that the UPS has lost input power?

DES-1721 Question 26

Options:

Buy Now
Questions 27

There has been a request to add iSCSI functionality to a SC9000 array for replication. SC is currently using slots 4 and 5 for SAS back end. Slots 2 and 3 for Fibre Channel front end.

How many slots are available for new half-height I/O Cards?

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 28

An alert for a failed disk is visible under the alerts tab. Where would someone navigate to, in Unisphere Central for SC Series to identify the failed drive and have a graphical representation showing where in the enclosure the failed drive is located?

Options:

A.

System menu, Hardware submenu, Disks

B.

Hardware tab, then Enclosure in navigation tree

C.

Storage menu, Disks

D.

Storage tab, then Disks in the navigation tree

Buy Now
Questions 29

Based on documented best practices, which options may need to be modified on a server QLogic HBA?

Options:

A.

Port Down Retry Count and Enable LIP Reset

B.

Enable Target Reset and Login Retry Count

C.

Port Down Retry Count and Enable Target Reset

D.

LUNs Per Target and Port Down Retry Count

Buy Now
Questions 30

To allow the Storage Center Update Utility (SCUU) to serve updates, which inbound TCP port should be opened on the Microsoft Windows firewall?

Options:

A.

443

B.

3033

C.

8443

D.

9005

Buy Now
Questions 31

What is the maximum memory supported on a single SC9000 controller?

Options:

A.

64 GB

B.

96 GB

C.

128 GB

D.

256 GB

Buy Now
Questions 32

You are trying to discover a brand new SCv3020 but the process if failing. DHCP is not available. What is the best solution for this issue?

Options:

A.

Enable MTU and flowcontrol on the switch

B.

Configure IPv4 address on the system running the DSM Client on the target subnet

C.

Set BMC IPs

D.

Configure IPv4 on DSM Client machine and enable IPv6 addressing

Buy Now
Questions 33

A customer is using an SC8000 array with three chained SC220 expansion enclosures on a single card. They need to expand its capacity by adding an SC280 enclosure. How should the new expansion enclosure be connected using a minimum number of chains?

Options:

A.

Add the SC280 to the same chain as the existing SC220 enclosures

B.

SC280 enclosures cannot be mixed with other enclosures

C.

Install a new SAS I/O card to connect the SC280 enclosure

D.

Add the SC280 to a new chain on the same SAS I/O card

Buy Now
Questions 34

Which SC Series array feature simplifies iSCSI connectivity and allows access to all ports through redirection?

Options:

A.

Legacy Port Mode

B.

ISNS

C.

ALUA

D.

Virtual Port Mode

Buy Now
Questions 35

You are going to install a SC Series running SCOS 7.3.x with 15K and 7K disks. What Data Reduction option will be available on this system?

Options:

A.

Deduplication

B.

Compression

C.

Compression with Rehydrate

D.

Deduplication with Compression

Buy Now
Questions 36

A customer is concerned they are over utilizing their 7K drives. Where can information about the real time I/O usage of individual drives be viewed?

Options:

A.

Hardware > Disks > [disk folder] > [disk number]

B.

Charting > Disks > [disk folder] IO Charts

C.

Charting > Disks > [disk folder] > [disk number]

D.

Hardware > Disks > [disk folder]

Buy Now
Questions 37

You are deploying a new SC9000 system running Storage Center OS 7.2. At which drive size does the system require you to begin running dual redundancy on both SSDs and HDDs?

Options:

A.

2.0 TB and larger for SSDs4.0 TB and larger for HDDs

B.

4.0 TB and larger for SSDs2.0 TB and larger for HDDs

C.

4.0 TB and larger for SSDs4.0 TB and larger for HDDs

D.

8.0 TB and larger for SSDs2.0 TB and larger for HDDs

Buy Now
Questions 38

Which datapage size options are available for SC Series arrays?

Options:

A.

512 KB, 1 MB, and 2 MB

B.

512 KB, 2 MB, and 4 MB

C.

1 MB, 2 MB, and 4 MB

D.

1 MB, 4 MB, and 8 MB

Buy Now
Questions 39

You are about to perform the post-setup tasks with the Storage-Center wizard. What information is required before proceeding?

Options:

A.

Customer contact information for the Storage Center

B.

Management IPv4 address for the Storage Center

C.

Email address for the default administrator

D.

NTP server IPv4 address for the Storage Center

Buy Now
Questions 40

Assume a storage administrator is using the recommended storage profile. What describes the distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-end?

Options:

A.

New and frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

B.

New data in Tier 1 RAID 10Frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

C.

New data in Tier 1 RAID 10Frequently accessed replay data in Tier 2 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

D.

New and frequently accessed replay data in Tier 1 RAID 10Aged replay data and inaccessible data in Tier 3 RAID 6

Buy Now
Questions 41

What can be done in order to facilitate the WWN Zoning and port identification in Brocade switches?

Options:

A.

Create Zones using WWPNs

B.

Create Aliases for port numbers

C.

Create Aliases for the WWPMs

D.

Create Zones using port numbers

Buy Now
Questions 42

Which statement is NOT correct for upgrading to SCOS version 07.03.01 and above?

Options:

A.

It does not allow the mixing 6 Gb and 12 Gb enclosures in a chain

B.

25 Gb and 100-Gb iSCSI HBAs are supported

C.

The absence of spares for any disk class folder blocks the upgrade

D.

The user is asked for permission to enable the Spare Optimizer

Buy Now
Questions 43

A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.

Which Windows MPIO policy should be configured to achieve the customer’s requirement?

Options:

A.

Fail Over Only

B.

Weighted Paths

C.

Round Robin with Subset

D.

Round Robin

Buy Now
Questions 44

Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts?

Options:

A.

Use dedicated switches for iSCSI.Two separate VLANS for multipathed iSCSI using separate IP subnets.Gigabit full duplex between Storage Center and all local servers.

B.

Use separate IP subnets for multipathed iSCSI separated by VLANS when using the same switch.Gigabit full duplex between Storage Center and all local servers

C.

Use separate switches for iSCSI.Two separate VLANs for multipathed iSCSI using separate IP subnets.Unicast and multicast storm control enabled on all iSCSI switches.

D.

Use separate VLANs for multipathed iSCSI using separate IP subnets when using the same switch.Bi-directional flow control disabled between Storage Center and servers.

Buy Now
Exam Code: DES-1721
Exam Name: Specialist - Implementation Engineer SC Series Exam
Last Update: Apr 30, 2026
Questions: 147

PDF + Testing Engine

$63.52  $181.49

Testing Engine

$50.57  $144.49
buy now DES-1721 testing engine

PDF (Q&A)

$43.57  $124.49
buy now DES-1721 pdf