Weekend Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: pass65

H13-624_V5.5 HCIP-Storage V5.5 Questions and Answers

Questions 4

A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 5

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

Options:

A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Buy Now
Questions 6

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

Options:

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

Buy Now
Questions 7

When delivering a flash storage project, Huawei engineers introduced the arbitration mechanism of HyperMetro to the customer. Which of the following statements is false about the arbitration modes?

Options:

A.

If no quorum server is configured, HyperMetro works in static priority mode. When an arbitration occurs, the preferred site wins the arbitration and provides services.

B.

In static priority mode, if the preferred site of a HyperMetro pair breaks down, the non-preferred site does not automatically take over HyperMetro services. As a result, the services stop, and the customer must forcibly start the services at the non-preferred site.

C.

In quorum server mode, the quorum server can be deployed only on physical machines and not on virtual machines.

D.

In quorum server mode, if the link between storage systems is down, each storage system sends an arbitration request to the quorum server.

Buy Now
Questions 8

An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?

Options:

A.

The main storage disk module is being located.

B.

The main storage disk module is running properly.

C.

The main storage disk module is powered off.

D.

The main storage disk module is faulty or about to fail.

Buy Now
Questions 9

A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?

Options:

A.

The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.

B.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.

C.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.

D.

If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Buy Now
Questions 10

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

Options:

Buy Now
Questions 11

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

Options:

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Buy Now
Questions 12

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

Options:

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Buy Now
Questions 13

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Buy Now
Questions 14

Assume a financial customer purchases several Huawei scale-out storage devices for service deployment. Unstructured services require multiple network planes. Which statement about the network planes is false?

Options:

A.

The internal management network is used for communication between storage and management nodes, including deployment and upgrade, resource configuration, performance alarm reporting, and certificate and key update.

B.

For the file service in the Distributed Parallel Client (DPC) scenario, the back-end storage network is available for communication with compute nodes to process communication data between the DPC and Object Storage Device (OSD).

C.

The management network is used for system management and maintenance. It is connected to the customer’s management network.

D.

The service network is connected to the customer’s application system and accesses the storage through the S3, HDFS, NFS, CIFS, and POSIX interfaces.

Buy Now
Questions 15

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 16

For Huawei flash storage, a user can configure the DME IQ service for upload logs, including performance logs and disk health analysis (DHA) logs. DHA logs refer to routine run logs of disks, which contain collected disk health and I/O statistics.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

Which of the following statements are false about direct TCP offload engine (DTOE) 1.0?

Options:

A.

This technology requires CPU to process each MAC frame, which will consume a large number of CPU resources.

B.

This technology allows to directly operate the hardware queue in the user mode, avoiding the context switching overhead.

C.

This technology uses the polling mode, reducing the latency.

D.

High latency overhead still exists using the technology, such as kernel mode interrupts, locks, system calls, and thread switching.

Buy Now
Questions 18

When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?

Options:

A.

Small I/Os are aggregated in the cache and then written to disks, achieving an ideal latency and improving the utilization of small files.

B.

Fixed-length large-granularity indexes are used to ensure sequential read/write performance of large I/Os.

C.

Large I/Os can be directly forwarded to the home node for processing, eliminating the overhead of scale-out locks and greatly reducing the read/write latency of large I/Os.

D.

In terms of I/O flow, large I/Os are written to disks in passthrough mode, improving the bandwidth capability.

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Jun 12, 2025
Questions: 60

PDF + Testing Engine

$57.75  $164.99

Testing Engine

$43.75  $124.99
buy now H13-624_V5.5 testing engine

PDF (Q&A)

$36.75  $104.99
buy now H13-624_V5.5 pdf