Pre-Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: pass65

H13-624_V5.5 HCIP-Storage V5.5 Questions and Answers

Questions 4

Huawei OceanStor Pacific series is an intelligent scale-out storage product that supports large-scale scale-out and delivers high reliability. Which of the following statements are false about the product’s reliability?

Options:

A.

In terms of data reliability, multiple RAID policies are supported based on the traditional disk-level RAID mode.

B.

The product adopts Kunpeng processors to integrate functions of multiple chips and effectively improve hardware reliability.

C.

The product leverages link aggregation to ensure transmission link redundancy and performs link switchover or isolation to ensure service continuity if a link becomes faulty or subhealthy.

D.

The product uses the multi-copy technology to implement the intra-node RAID function. If a node is faulty, the system reliability is not degraded and even remains higher than that of the EC mechanism.

Buy Now
Questions 5

Huawei flash storage supports HyperReplication, which is mainly used in data disaster recovery and backup scenarios. Which of the following statements are true about this feature?

Options:

A.

Secondary resource protection refers to the process of suspending the remote replication relationship between the primary and secondary volumes.

B.

A pair refers to the data replication relationship between the primary and secondary LUNs. When the pair running status is "Normal", data is successfully synchronized between the primary and secondary LUNs.

C.

A consistency group is a collection of pairs that have a service relationship with each other.

D.

Synchronization is the process of copying data from a primary volume to a secondary volume.

Buy Now
Questions 6

A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?

Options:

A.

The engineer has manually adjusted the time of the cluster nodes. As a result, the conflict handling is different.

B.

NTP synchronization is not configured for the cluster, and different NTP time sources are used.

C.

Namespaces with the same name have been created under the same account.

D.

The Network Time Protocol (NTP) clock in the storage cluster is inconsistent with the clock of the client that accesses object services.

Buy Now
Questions 7

During the use of Huawei flash storage, an engineer wants to calculate the valid write bandwidth of disks. Which of the following formulas can calculate disk valid write bandwidth?

Options:

A.

Valid read bandwidth of disks = Read bandwidth of a single disk x Number of disks x (Number of system disks / Total number of disks)

B.

Valid write bandwidth of disks = Write bandwidth of a single disk x Number of disks

C.

Valid write bandwidth of disks = Write bandwidth of a single disk x Number of disks x (Number of data disks / Total number of disks)

D.

Valid write bandwidth of disks = Bandwidth of a single port x Number of ports

Buy Now
Questions 8

After a remote replication consistency group is created, if one remote replication task is faulty, other tasks in the consistency group run normally without waiting for the faulty task to recover.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 9

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

Options:

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

Buy Now
Questions 10

Assume an Industry customer purchased a Huawel flash storage device for service deployment. After a fault occurs, an engineer needs to use the CLI to view bit error Information of front end host ports for troubleshooting. Which of the following commands cannot be used for this purpose?

Options:

A.

show coexist-forward-switch

B.

show controller io io_type=frontEnd controller_id=XX

C.

show port biLerror

D.

show host-port error

Buy Now
Questions 11

During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 12

When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?

Options:

A.

Small I/Os are aggregated in the cache and then written to disks, achieving an ideal latency and improving the utilization of small files.

B.

Fixed-length large-granularity indexes are used to ensure sequential read/write performance of large I/Os.

C.

Large I/Os can be directly forwarded to the home node for processing, eliminating the overhead of scale-out locks and greatly reducing the read/write latency of large I/Os.

D.

In terms of I/O flow, large I/Os are written to disks in passthrough mode, improving the bandwidth capability.

Buy Now
Questions 13

A financial customer purchases several Huawei flash storage devices for service deployment. During routine storage management. If an engineer logs In to a storage device as a data protection administrator, which of the following operations can the engineer perform?

Options:

A.

Managing the antivirus (unction

B.

Managing HyperCDP objects and snapshot consistency groups

C.

Managing clone consistency groups and LUN consistency groups

D.

Managing security policies and security rules

Buy Now
Questions 14

During routine O & M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

Options:

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Buy Now
Questions 15

When delivering a flash storage project, Huawei engineers Introduced the SmartMuIti-Tenant feature of flash storage to the customer. Which of the following statements are true about SmartMulti Tenant?

Options:

A.

A super administrator can force itself, other super administrators, lightweight directory access protocol (LDAP) users, or LDAP user groups to change their passwords upon the next login.

B.

After a system is upgraded to support the SmartMulti-Tenant feature, all LUNs, file systems, and ports in the original system are allocated to the internal system vStore "System_vStore."

C.

To query system role information, the customer can run the "show role system" command.

D.

In flash storage, only a super administrator can modify vStore information, and the internal system vStore "System_vStore" cannot be modified.

Buy Now
Questions 16

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

Options:

A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Buy Now
Questions 17

In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?

Options:

A.

Cache hit ratio of hot metadata

B.

CPU usage of metadata background management

C.

Whether failover is enabled for protocol receiving threads

D.

Hit ratio of the prefetch algorithm

Buy Now
Questions 18

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

Options:

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Buy Now
Questions 19

An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

Options:

A.

change domain ad_manager operation=develop

B.

change dns general address=develop

C.

change user_mode current_mode user_mode=developer

D.

change nas_Idap advanced_config

Buy Now
Questions 20

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Buy Now
Questions 21

A financial customer purchased a Huawei flash storage system for service deployment. An engineer configured the HyperClone feature on the storage system. If the running status of a clone consistency group (CG) is "DiffCopy reverse syncing" or "Unsynchronized", the engineer cannot delete the clone CG.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 22

A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?

Options:

A.

Controller enclosure backplane

B.

BBU

C.

Disk

D.

Interface module

Buy Now
Questions 23

The _____ feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Options:

Buy Now
Questions 24

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 25

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Buy Now
Questions 26

A financial customer purchased an OceanStor Dorado 18000 storage system for basic service deployment. During management, an engineer discovered that the running status of an iSCSI port on DeviceManager was "Link down". After checking the indicator in the equipment room, the engineer discovered that the link indicator of the iSCSI front-end port was steady red. Which of the following are not the possible causes of the exception?

Options:

A.

The optical module type is incompatible with the host port.

B.

The IP address of the iSCSI front-end port is incorrect.

C.

The cable between the application server and the storage device is loose.

D.

The IP address of the service network port on the application server is incorrectly set.

Buy Now
Questions 27

When delivering a Huawei flash storage project, an engineer introduced the SAN/NAS Integrated architecture to the customer. Which of the following statements Is false about the architecture?

Options:

A.

The protocol layer is responsible for protocol parsing and permission management. SAN and NAS are two sets of semantic logic. Therefore, different service entry components are used.

B.

The space management layer uses the active-active high reliability mode to provide reliable data protection capabilities based on actual service scenarios of customers.

C.

The software architecture consists of the following layers from top to bottom: protocol, data service, cache, file and block space management, and storage pool.

D.

At the protocol layer, NFS/CIFS supports direct TCP offload engine (DT06), while ISCSI does not.

Buy Now
Questions 28

For device reliability purposes, during the quick Installation of OceanStor Pacific 9550, engineers need to connect power cables on the storage device supplied by two power modules to separate power distribution units (PDUs).

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 29

An Industry customer purchases several Huawei flash storage devices for service deployment. During an inspection, an engineer finds that some storage components are faulty and need to be removed and replaced. Which of the following statements Is true about the part removal and replacement?

Options:

A.

The interface modules and system subracks of the storage device can be replaced independently.

B.

The CPUs of the storage device cannot be replaced independently, but can be removed independently.

C.

The memory modules and system disks of the storage device can be removed and replaced independently.

D.

The coin batteries of the storage device cannot be replaced or removed.

Buy Now
Questions 30

A financial customer has purchased multiple Huawei OceanProtect Backup Storage devices for service data backup protection. Which of the following statements are false about the data reduction principle of OceanProtect Backup Storage? choose all that apply

Options:

A.

The backup storage can perform deduplication and compression for LUNs but not for file systems.

B.

In the data reduction process, the system performs backup data preprocessing and then variable-length deduplication.

C.

The backup storage performs feature-based compression for different application data. After compression, the data can be directly written to disks without the need to perform any operations.

D.

In the data reduction process, backup data is divided into blocks of a fixed size based on its content for fixed-length deduplication.

Buy Now
Questions 31

During routine O & M, if an engineer finds that the system disk and some interface modules of a flash storage device are faulty, the engineer can directly remove and replace the faulty parts.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 32

A government customer has purchased several Huawei scale-out storage devices, and an engineer wants to install the distributed parallel client (DPC). When creating DPC nodes, the engineer can manually add a node by entering the service IP address of the node.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 33

When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 34

Huawei OceanProtect Appliance provides strong data protection capabilities. Which of the following statements is true about the functional architecture of the Appliance?

Options:

A.

ProtectManager is a data flow module that performs data backup, restoration, replication, archive, and copy mounting.

B.

File system management and protocol access are implemented by the data protection layer.

C.

During data protection, the Appliance can protect application data without backup agents.

D.

DataEnable Engine is a data enabling module for global search and data anonymization.

Buy Now
Questions 35

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Buy Now
Questions 36

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Buy Now
Questions 37

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

Options:

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Apr 10, 2026
Questions: 125

PDF + Testing Engine

$63.52  $181.49

Testing Engine

$50.57  $144.49
buy now H13-624_V5.5 testing engine

PDF (Q&A)

$43.57  $124.49
buy now H13-624_V5.5 pdf