H19-311 Huawei Certified Pre-sales Associate- Data Center Facility Questions and Answers

Questions 4

The pipe routing method for the FusionModule800 is ().

Options:

A.

Top and bottom pipe routing

B.

Bottom pipe routing

C.

Top pipe routing

Buy Now
Questions 5

Which of the following are the functions of the SCT configurator? () (Multiple Choice)

Options:

A.

Display product cost data

B.

Provide quick overview of Huawei products

C.

Quick solution configuration

D.

Simple quotation creation

Buy Now
Questions 6

What type of air conditioner does the Fusion Mod ule800 basic configurations adopt? () (Multiple Choice)

Options:

A.

In-row air conditioner

B.

Rack-mounted air conditioner

C.

Air cooling

D.

Water cooling

E.

Air conditioner with a heater and humidifier

F.

Cooling only

Buy Now
Questions 7

The UPS5000-A features industry-leading reliability. Which of the following statements is correct about the UPS5000-A reliability design? (Multiple Choice)

Options:

A.

Strong power grid adaptability, 138-485 V voltage input range

B.

Conformal coated board

C.

Test guarantee of 1,400 items

D.

40°C without derating

Buy Now
Questions 8

The standard protection level of the UPS5000-A is ( ).

Options:

A.

IP22

B.

IP21

C.

IP20

Buy Now
Questions 9

The control unit of the UPS5000-A adopts 1+1 redundancy. A faulty control unit can be smoothly switched to the other, which can prevent the occurrence of single-point failures and improve the power supply reliability.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 10

With parallel configuration, the UPS2000-G supports the use of a single () card for multiple UPSs in parallel. (Multiple Choice)

Options:

A.

SNMP

B.

Modbus

C.

Dry contact

D.

Parallel

Buy Now
Questions 11

Which of the following parallel system does the UPS5000-A support? (Multiple Choice)

Options:

A.

N+X parallel system

B.

Dual-bus system

C.

Parallel system not supported

Buy Now
Questions 12

Which of the following are the monitoring methods used by the UPS2000-A series (6 kVA to 10 kVA) with an SNMP card? (Multiple Choice)

Options:

A.

NetEco

B.

WebUI

C.

SMU2000

Buy Now
Questions 13

When using a UPS5000-E (50 kVA power module) with the actual load of 160 kW, 1+1 rack redundancy, and single UPS backup solution, each rack uses three battery strings, each battery string consists of 40 batteries, and the main switch box capacity is ().

Options:

A.

250A

B.

320 A

C.

500 A

D.

630 A

Buy Now
Questions 14

The DC cable voltage drop must be within ( ).

Options:

A.

0.01

B.

0.02

C.

0.03

D.

0.05

Buy Now
Questions 15

The UPS2000-G-20KRTL is rack/tower convertible. The rack-mounted model is () high.

Options:

A.

1U

B.

2U

C.

3U

D.

4U

Buy Now
Questions 16

NetEco solution can be configured in FusionModule2000 solution.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

Which of the following statements are incorrect about the UPS 5000-A-400/500K? (Multiple Choice)

Options:

A.

The input power factor is 0.99.

B.

The output power factor is 1.

C.

The number of batteries cannot be adjusted.

D.

The efficiency is 94%.

Buy Now
Questions 18

Which of the following statements are true about the overload capabilities of the various capacity models of the UPS2000-A series (6 kVA to 10 kVA) in normal mode? () (Multiple Choice)

Options:

A.

105%-125%, switch to bypass after 5-miunute continuous loading

B.

125%-150%, switch to bypass after 1-miunute continuous loading

C.

> 150%, switch to bypass after 10s continuous loading

D.

> 150%, switch to bypass after 0.1s continuous loading

Buy Now
Questions 19

The number of batteries can be adjusted in the process of UPS configuration.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 20

For the UPS2000-G series (6 kVA to 20 kVA), the main input voltage ranges from 80 V to 280 V, and the input frequency ranges from 40 Hz to 70 Hz. A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 21

According which of the following statements can you determine that the battery is faulty? (Multiple Choice)

Options:

A.

The voltage increase of a battery is faster than the other batteries.

B.

The temperature of the battery string during discharge is 2°C higher than the surrounding ambient temperature.

C.

A battery suffers from obvious bulge and leakage.

D.

The voltage drop of a battery is obviously faster than the other batteries.

Buy Now
Questions 22

The bypass module in the UPS5000-E-200K is the same as that in the UPS5000-E-400K.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 23

Which of the following is the operating principle of the UPS2000-G? ()

Options:

A.

Online interactive UPS

B.

Online dual-conversion

C.

Standby

D.

Delta conversion

Buy Now
Questions 24

What is the maximum number of U cabinets used by the FusionModule2000 with a built-in UPS (N+l power architecture)? ()

Options:

A.

12

B.

24

C.

42

D.

48

Buy Now
Questions 25

The UPS2000-G supports low voltage disconnection. Which of the following is not a function of low voltage disconnection? ()

Options:

A.

When overload occurs, secondary loads are closed to remove the overload.

B.

When the UPS2000-G is powered by batteries, secondary loads are closed to prolong the backup time for important loads.

C.

When the UPS2000-G is powered by batteries, secondary loads are closed for battery protection.

D.

The purpose of closing secondary loads is to adjust the load ratio and optimize the operating efficiency.

Buy Now
Questions 26

The UPS5000-S efficiency is ().

Options:

A.

0.96

B.

0.965

C.

0.971

D.

0.975

Buy Now
Questions 27

Do the aisles of the FusionModule800 have skylights? ()

Options:

A.

Yes

B.

No

Buy Now
Questions 28

The battery voltage of the UPS2000-G is 240 V for the 6-10 kVA capacity models, and is 480 V for the 15 kVA and 20 kVA capacity models.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 29

Which of the following actions does the UPS2000-G take when the main input exceeds the allowable range? ()

Options:

A.

Switch to battery mode.

B.

Switch to bypass.

C.

Initiate overvoltage protection or undervoltage protection.

D.

Initiate derating and continue operating.

Buy Now
Questions 30

The UPS5000-E battery adopts the design without neutral wire, which facilitates battery re-utilization in the replacement of a tower-mounted UPS.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 31

The Fusion Mod ule500 adopts free cooling.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 32

The capacity of the UPS5000-S power module is 50 kVA, and the height is 2U, which ranks the top in the power density of the industry.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 33

A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life. The input voltage range of the UPS2000-G series (6 kVA to 20 kVA) is ( ).

Options:

A.

80-280 V

B.

120-280 V

C.

120-300 V

D.

160-300 V

Buy Now
Questions 34

Maintenance services cannot be configured in Unistar SCT.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 35

The communication modes in a standard UPS5000-A include: (Multiple Choice)

Options:

A.

Dry contact

B.

RS485

C.

RS232

D.

SNMP

Buy Now
Questions 36

The UPS backup duration is typically within 30 minutes. It is reasonable to calculate the battery capacity with the galvanostatic method.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 37

The UPS5000 is compatible with module and tower.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 38

The maximum capacity of a single-racked UPS5000-E (50 kVA power module) is 300 kVA.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 39

Which of the following elements will affect the application of HVDC in the equipment room? (Multiple Choice)

Options:

A.

The standard is not complete, and multiple 240 V/336 V systems exist.

B.

Not all loads can use the DC power supply directly,

C.

The cost of DC circuit breaker components is high.

D.

The efficiency is low.

Buy Now
Questions 40

The FusionModule500 license is free for up to 50 sites, but is charged for more than 50 sites.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 41

The UPS5000-E features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-E?

Options:

A.

305-485 V

B.

105-485 V

C.

138-485 V

Buy Now
Questions 42

Which of the following is not the certifications obtained by the UPS2000-G series? ()

Options:

A.

Enhanced Capital Allowance (ECA) tax allowance

B.

Energy Star certification

C.

Green Sites award

D.

CE certification

Buy Now
Questions 43

Which of the following components is included in the UPS5000-E (25-75 kVA)? (Multiple Choice)

Options:

A.

Input switch

B.

Output switch

C.

Battery switch

D.

Maintenance bypass switch

Buy Now
Questions 44

Which of the following statements are correct? (Multiple Choice)

Options:

A.

When configuring the UPS2000-G 15K and apply the 4+0 parallel system, you can use one SNMP card to realize monitoring.

B.

When configuring the UPS5000-E, you can use an unlimited number of modules in parallel.

C.

Batteries of different brands and capacities can be used together.

D.

When configuring the cable, you shall consider the voltage drop in the route.

Buy Now
Questions 45

The output terminal type of the 6-kVA UPS2000-G is ( ).

Options:

A.

Terminal block

B.

C13

C.

Terminal block+C13

D.

Terminal block+socket compliant with international standards

Buy Now
Questions 46

The backup power supply methods for the FusionModule500 and FusionModule800 include (). (Multiple Choice)

Options:

A.

Battery rack

B.

Battery cabinet deployed outside the aisle containment

C.

Battery cabinet deployed inside the aisle containment

D.

Battery pack

Buy Now
Questions 47

The output capacity of a single UPS is calculated on actual power when the actual load power is used for UPS configuration.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 48

The number of UPS5000-E batteries can be adjusted. When one battery becomes faulty, you should remove at least () batteries and set the corresponding battery quantity on the monitoring panel.

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 49

Which of the following voltage systems does the UPS5000-E support? (Multiple Choice)

Options:

A.

380 V

B.

415 V

C.

480V

D.

400 V

Buy Now
Questions 50

What UPS configuration method does the Fusion Mod ule800 support? ()

Options:

A.

N/2N

B.

N/N+1

C.

N/N+1/2N

Buy Now
Questions 51

The UPS5000-A has a built-in isolation transformer.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 52

By default, how many POUs are configured for one cabinet of the FusionModule2000? ( )

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 53

Which of the following statements are correct about the UPS5OO0-A-400/500K usability? (Multiple Choice)

Options:

A.

The parallel board is configured.

B.

The UPS floor area is only 1.02 m2.

C.

The number of batteries is adjustable.

D.

Smart battery management is supported.

Buy Now
Questions 54

The optional components and features in the typical configuration solution of the FusionModule500 include ().

Options:

A.

Huawei tablet, alarm notification over short messages, video surveillance, mobile app, and switch

B.

Huawei tablet, alarm notification over short messages, video surveillance, water sensor, and smoke sensor

C.

Huawei tablet, alarm notification over short messages, mobile app, water sensor, and door status sensor

Buy Now
Questions 55

Considering that the UPS is fully configured but has a low system load rate in the initial stage, the UPS5000-E is designed with a smart hibernation function, which can improve system load rate to ensure highly efficient operation. In case of smart hibernation, how many redundant power modules does the UPS5000-E have at least?

Options:

A.

0

B.

1

C.

2

Buy Now
Questions 56

The UPS5000-E (25-75 kVA) has the industry-leading lightning protection. Its lightning protection level is (), and surge protection level is (). Compared with the other similar UPSs in the industry, it can efficiently reduce the lightning strike failure rate.

Options:

A.

5 kA; 6 kV

B.

2 kA; 4 kV

C.

2 kA; 6 kV

D.

4 kA; 6 kV

Buy Now
Questions 57

Are the air conditioners of the Fusion Mod ule800 connected to the back end of UPSs? ()

Options:

A.

Yes

B.

No

Buy Now
Questions 58

Which of the following battery configuration are unreasonable for the UPS5000-A? (Multiple Choice)

Options:

A.

Thirty-two 12 V batteries

B.

Thirty-seven 12 V batteries

C.

Forty 12 V batteries

D.

Forty-two 12 V batteries

Buy Now
Questions 59

Which of the following statements are correct about the UPS5000-A-500K efficiency? (Multiple Choice)

Options:

A.

The efficiency is 96%.

B.

The efficiency is 94%.

C.

The efficiency is 99% under ECO mode.

D.

The efficiency is 98% under ECO mode.

Buy Now
Questions 60

The UPS5000-E has strong load adaptability. It does not derate in case of leading/lagging capacitive/inductive loads.

Options:

A.

0.4

B.

0.5

C.

0.6

D.

0.7

Buy Now
Questions 61

The UPS2000-G series (6 kVA to 20 kVA) has the () user interface, which displays the system status in real time.

Options:

A.

LED

B.

LCD

C.

Touchscreen

D.

Remote NMS

Buy Now
Questions 62

The UPS5000-E can realize convenient and simple 2N power supply system only by configuring a ().

Options:

A.

BSC cable

B.

Synchronized control

C.

BSC control board

D.

Parallel card

Buy Now
Questions 63

The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.

Options:

A.

0

B.

2

C.

3

D.

4

Buy Now
Questions 64

What's difference of a traditional industrial frequency UPS compared with high frequency UPS? (Multiple Choice)

Options:

A.

The rectifier system is different.

B.

A built-in boosting transformer is required for output.

C.

The bypass component type is different.

D.

All of the above are correct.

Buy Now
Questions 65

The UPS5000-E (25-125 kVA) power module height is (), and the system efficiency is ( ).

Options:

A.

3U, 95.5%

B.

3U, 96%

C.

2U, 95.5%

D.

2U, 96%

Buy Now
Questions 66

A UPS with a high input power factor allows for effective power grid utilization and reduced power grid interference. The input power factor of the UPS2000-A series (1 kVA to 3 kVA) is ().

Options:

A.

0.85

B.

0.9

C.

0.95

D.

0.99

Buy Now
Questions 67

Which of the following elements shall be considered when configuring a UPS? (Multiple Choice)

Options:

A.

UPS model, capacity, and parallel system mode

B.

Battery brand and capacity

C.

Brand and model of the AC and DC cables

D.

Configuration of the battery rack and battery switch box

Buy Now