ITFAS-Level-1 Inspection and Testing of Fire Alarm Systems Level I Exam Questions and Answers

Questions 4

Which three of the following are types of fire alarm control units? (Choose three.)

Options:

A.

Central station

B.

Dedicated function

C.

Protected premises

D.

Releasing service

Buy Now
Questions 5

At which height above the floor is the sound level measured for public and private modeaudible devices?

Options:

A.

2.5 feet (0.7 meter)

B.

5.0 feet (1.5 meters)

C.

7.5 feet (2.3 meters)

D.

8.0 feet (2.4 meters)

Buy Now
Questions 6

When testing initiating devices, what is the maximum allowed time for the supervising station to verify receipt of the signal?

Options:

A.

60 seconds

B.

80 seconds

C.

90 seconds

D.

120 seconds

Buy Now
Questions 7

When is the elevator recall permitted to send a supervisory signal in lieu of an alarm signal?

Options:

A.

Where approved by the authority having jurisdiction

B.

Where approved by the building owner

C.

Where approved by the insurance company

D.

Where approved by the system designer

Buy Now
Questions 8

When shall the elevator alternate level recall function be initiated?

Options:

A.

In response to activation of a smoke detector located at the designated elevator lobby

B.

In response to activation of a smoke detector located on a floor above designated lobby

C.

When elevator Phase I recall fails to initiate

D.

With activation of a general building alarm

Buy Now
Questions 9

How often are manual fire alarm boxes inspected?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Questions 10

Which three of the following branch circuit characteristics are required for circuit identification and accessibility of the fire alarm equipment's primary power supply? (Choose three.)

Options:

A.

The system circuit disconnect shall be permanently identified as "Fire Alarm."

B.

The system circuit disconnect shall be permanently identified at the control unit.

C.

Where a circuit breaker is the disconnecting means, a breaker locking device shall be installed.

D.

Where a circuit breaker is the disconnecting means, a breaker locking device shall be labeled.

Buy Now
Questions 11

Smoke detector activation in the ninth-floor elevator lobby shall activate which of the following functions?

Options:

A.

Alternate level recall

B.

Designated level recall

C.

Ninth-floor supervisory signal

D.

Ninth-floor trouble signal

Buy Now
Questions 12

How far away from the center line of the elevator door can a smoke detector be located?

Options:

A.

3 feet (1.0 meter)

B.

5 feet (1.5 meters)

C.

12 feet (3.7 meters)

D.

21 feet (6.4 meters)

Buy Now
Questions 13

Visible and audible trouble signals shall be indicated at which two of the following locations? (Choose two.)

Options:

A.

Alarm company office

B.

Emergency command center

C.

Fire alarm control unit

D.

Fire department headquarters

Buy Now
Questions 14

How often should radio transmitters be inspected?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Questions 15

How is a lead-acid battery inspected?

Options:

A.

By checking for damage

B.

By checking voltage

C.

By verifying specific gravity

D.

By verifying the charging circuit

Buy Now
Questions 16

Which two of the following are needed to perform a periodic test of a projected beam type smoke detector? (Choose two.)

Options:

A.

Blocking the transmitter

B.

Introducing smoke

C.

Using a listed test switch

D.

Using an optical filter

Buy Now
Questions 17

When is a shunt trip operated to power down an elevator?

Options:

A.

When a heat detector is tripped

B.

When a pull station is activated

C.

When a smoke detector is tripped

D.

When a sprinkler head is activated

Buy Now
Questions 18

The minimum supervising station signaling requirement for a fire alarm system that monitors a sprinkler flow and tamper switch shall include which set of signals?

Options:

A.

Alarm, trouble, and phone line failure

B.

Alarm, trouble, and supervisory

C.

Alarm, trouble, supervisory, and daily test

D.

Alarm, trouble, supervisory, and primary power

Buy Now
Questions 19

How often does a technician test the manual operation of a master box on a public emergency alarm reporting system?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Questions 20

According to NFPA 72, which date shall be marked on batteries?

Options:

A.

Month and year of expiration

B.

Month and year of inspection

C.

Month and year of installation

D.

Month and year of manufacture

Buy Now
Questions 21

A disconnection of the primary phone line shall cause which of the following events to occur?

Options:

A.

Activation of notification appliance

B.

Local annunciation only

C.

Notification via secondary phone line

D.

Supervisory condition

Buy Now
Questions 22

What is the adjustment range for smoke detectors that have a provision for field adjustment of sensitivity?

Options:

A.

No less than 0.6% per foot (1.95% per meter)

B.

No more than 0.6% per foot (1.95% per meter)

C.

No more than 1.2% per foot (3.90% per meter)

D.

No less than 1.2% per foot (3.90% per meter)

Buy Now
Questions 23

An off-normal signal shall be initiated during which of the following travel distances of the valve control apparatus from its normal position?

Options:

A.

1/5

B.

1/4

C.

1/3

D.

1/2

Buy Now
Questions 24

Prior to any testing, all persons and facilities receiving signals and all occupants need to be notified of the testing to prevent which of the following issues?

Options:

A.

Critical system shutdown

B.

Elevator usage

C.

Facility evacuation

D.

Unnecessary response

Buy Now
Questions 25

Which NFPA standard determines the testing of a carbon monoxide device or system?

Options:

A.

12

B.

70

C.

72

D.

101

Buy Now
Exam Code: ITFAS-Level-1
Exam Name: Inspection and Testing of Fire Alarm Systems Level I Exam
Last Update: Jul 1, 2025
Questions: 85