March Special Sale Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 713PS592

NCSC-Level-1 Nutanix Certified Services Consultant (NCSC): Level 1 Questions and Answers

Questions 4

After imaging the nodes and creating the cluster successfully, the consultant connects the cluster to the customer network. When logging into Prism, the events dashboard is full of errors.

What is causing the issue?

Options:

A.

The cluster was not stopped prior to connecting to the customer network.

B.

The Cluster Virtual IP Address (VIP) was not set up during the process.

C.

Foundation did not create the cluster successfully.

D.

The consultant did not run Nutanix Cluster Check (NCC..

Buy Now
Questions 5

A consultant creates a Nutanix cluster using the 10.10.10.0/24 network and VLAN 10. The customer creates a VM network inside the Prism using VLAN 20. The customer starts to create VMs but is unable to ping the default gateway from these new systems.

What is causing the issue?

Options:

A.

The CVM/hypervisor must be on an untagged VLAN.

B.

The switch port is not set up as a trunk.

C.

Only one VLAN is supported on AHV.

D.

The CVM/hypervisor cannot use the same VLAN as guest VMs.

Buy Now
Questions 6

A consultant is unable to install virtualization software on a laptop.

Which two versions of Foundation can be used to resolve this issue? (Choose two.)

Options:

A.

Foundation VM

B.

Foundation Portable

C.

Foundation Central

D.

Foundation Applet

Buy Now
Questions 7

A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.

The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.

What is causing this issue?

Options:

A.

The customer has LACP fallback enabled on switch ports.

B.

The hosts have not been migrated to a vSphere Distributed Switch.

C.

Under the vSwitch0 settings, the consultant did not select Route based on IP hash.

D.

The host and CVM are incorrectly configured.

Buy Now
Questions 8

A consultant notices while assigning VLAN tags to hosts and CVMs in a running cluster, that Prism Element displays alerts indicating a node is down.

What should the consultant do to prevent these alerts?

Options:

A.

Restart the Nutanix cluster.

B.

Only change the Controller Virtual Machine VLANs.

C.

Only change the hypervisor VLANs.

D.

Stop the Nutanix cluster before changing VLANs.

Buy Now
Questions 9

A customer wants to expand an existing cluster with three additional nodes. After running the Foundation process on the new nodes, the customer realizes that the wrong IPs where used and the nodes are configured on a different network. The customer decides to create a new cluster instead.

Which method should be used to recreate the cluster?

Options:

A.

Log into IPMI and use cluster create command to create the cluster.

B.

Log into CVM and use cluster create command to create the cluster.

C.

Log into Hypervisor and use cluster create command to create the cluster.

D.

Foundation all nodes again and create the cluster.

Buy Now
Questions 10

A consultant is setting up a new vSphere cluster. Customer requirements are as follows:

* VMs should automatically failover to another host if the host crashes

* Host CPU and Memory resources should be evenly balanced

* New VMs should be placed on the host with the most resources available

Which two settings should be turned on to meet the requirements? (Choose two.)

Options:

A.

vShpere DRS

B.

vSphere HA

C.

vSphere vMotion

D.

vSphere Power Management

Buy Now
Questions 11

After a recent installation using a flat switch, a consultant notices issues migrating the Nutanix nodes to the customer’s network. The customer states that they are using VLANs on the production switch but not on the dedicated switch for IPMI. The customer does not require a manual configuration of the host and CVM.

What network changes need to be made to correct the issues?

Options:

A.

Us untagged VLANs for the CVM and host and trunk mode for IPMI.

B.

Use Native VLANs for the CVM and host and access mode for IPMI.

C.

Use tagged VLANs for the CVM and host and access mode for IPMI.

D.

Use Native VLANs for the CVM and host and trunk mode for IPMI.

Buy Now
Exam Code: NCSC-Level-1
Exam Name: Nutanix Certified Services Consultant (NCSC): Level 1
Last Update: Mar 25, 2024
Questions: 78

PDF + Testing Engine

$66.4  $165.99

Testing Engine

$46  $114.99
buy now NCSC-Level-1 testing engine

PDF (Q&A)

$42  $104.99
buy now NCSC-Level-1 pdf