Spring Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: pass65

NS0-162 NetApp Certified Data Administrator (ONTAP) Questions and Answers

Questions 4

Due to the increasing threat of ransomware, you must implement a secure and fast solution to recover files in your ONTAP cluster. The users should be able to recover their files from their Windows Desktop.

In this scenario, which two steps fulfill this requirement? (Choose two.)

Options:

A.

Ensure that there is a Snapshot copy schedule for every volume containing files.

B.

Ensure that the option to show previous versions on the SVM Is activated.

C.

Ensure that the option to copy a FlexClone of each volume containing files is activated.

D.

Ensure that the option to show previous versions on each share is activated.

Buy Now
Questions 5

Exhibit

NS0-162 Question 5

You have a 4-node cluster.

How many ISCSI LIFs will be created from the SVM setup wizard, as shown in the exhibit?

Options:

A.

8

B.

6

C.

16

D.

2

Buy Now
Questions 6

You are planning an installation of a new stack of shelves to an HA pair and need to locate empty SAS ports...

In this scenario, which tool would you use to accomplish this task remotely?

Options:

A.

ONTAP System Manager

B.

Active IQ Web site

C.

Hardware Universe

D.

Interoperability Matrix Tool

Buy Now
Questions 7

You are currently using SnapMlrror Synchronous (SM-S) to protect a critical workload at your organization and you want to convert the SnapMlrror policy from Sync to StrictSync.

In this scenario, which procedure allows you to achieve this task?

Options:

A.

Recreate the SnapMirror relationship, specifying the strictsync policy, then re-synchronize it.

B.

Modify the existing SnapMirror relationship specifying the strictsync policy, then re-synchronize It.

C.

Recreate the SnapMlrror relationship, specifying the strictsync policy, then promote It.

D.

Modify the existing SnapMirror relationship specifying the strictsync policy, then promote It.

Buy Now
Questions 8

You are asked to deploy a 2-node ONTAP Select cluster. The physical hardware Is located In two different locations and you want the aggregates mirrored synchronously between the two data centers. You must ensure high availability and automated switchover.

In this scenario, which two steps would you take to fulfill this requirement? (Choose two.)

Options:

A.

Ensure that the ONTAP Select Deploy VM resides at a third location other than the two data centers.

B.

Install the SnapMirror Sync license on the cluster.

C.

Use ONTAP Mediator service to make sure that you have a quorum for the two nodes.

D.

Use ONTAP Select Deploy to Install the nodes on the physical hardware.

Buy Now
Questions 9

You need to configure data-at-rest encryption for your NetApp ONTAP 9.8 cluster. Your company does not have Key Management Interoperability Protocol (KMIP) services available but must require a passphrase to be entered when a node Is rebooted.

In this scenario, which two actions should be performed to satisfy these requirements? (Choose two.)

Options:

A.

Configure an external key management server.

B.

Enable onboard key management.

C.

Enable cluster-wide FlPS-compliant mode.

D.

Enable common criteria mode.

Buy Now
Questions 10

After attempting to perform an ONTAP upgrade. It falls during the pre-check. In this scenario, what would cause this problem?

Options:

A.

encrypted volumes

B.

offline volume

C.

Idle SnapMirrors

D.

offline data LIF

Buy Now
Questions 11

You need to Increase the number of files that can be created In a volume. Which two methods enable you to achieve this goal? (Choose two.)

Options:

A.

Increase the number of files permitted on the volume.

B.

Set the space guarantee to 'volume".

C.

Set the fractional reserve to "0".

D.

Increase the size of the volume.

Buy Now
Questions 12

All SMB users are reporting that their network share performance Is slow on a new NetApp FAS500f HA pair. You determine that the users have converged network adapters (CNAs) with flow control enabled and no option to disable.

In this scenario, which two flow control settings are recommended on the NetApp ONTAP physical ports? (Choose two.)

Options:

A.

Disable flow control end-to-end on data network ports.

B.

Enable flow control end-to-end on cluster network ports.

C.

Enable flow control end-to-end on data network ports.

D.

Disable flow control end-to-end on cluster network ports.

Buy Now
Questions 13

You want to monitor system performance in real time.

In this scenario, which two tools would you use to accomplish this task? (Choose two.)

Options:

A.

ONTAP System Manager

B.

Active IQ Unified Manager

C.

ONTAP CLI

D.

Active IQ Digital Advisor

Buy Now
Questions 14

Your company wants their newly Installed ONTAP system to automatically send telemetry data to NetApp to provide early notification of any security risks, bug fixes, and ONTAP updates. Furthermore, In case of hardware failures, a support case should be opened automatically at NetApp.

Which two NetApp components satisfy the requirements? (Choose two.)

Options:

A.

Cloud Insights

B.

Active IQ

C.

ONTAP AutoSupport

D.

Active IQ Unified Manager

Buy Now
Questions 15

After creating several volumes, you notice that the hosting aggregates Immediately show a decrease In available space. Which volume setting would prevent this outcome?

Options:

A.

space SLO set to "thick"

B.

space guarantee set to "none"

C.

space SLO set to "semi-thick"

D.

space guarantee set to "volume"

Buy Now
Questions 16

Exhibit.

NS0-162 Question 16 The availability of the remote cluster in the peering relationship shows "Partial."

Referring to the exhibit, what is the reason for this status message?

Options:

A.

The remote cluster does not have its cluster license applied properly.

B.

The local cluster is unable to authenticate successfully to the remote cluster.

C.

Some nodes in the local cluster are not able to contact some or all nodes in the remote cluster.

D.

The Intercluster LIFs on the local cluster are unavailable and not able to communicate to the remote cluster.

Buy Now
Questions 17

Which security method would be used to authenticate targets and Initiators In an ISCSI environment?

Options:

A.

NIS

B.

LDAP

C.

/etc/hosts

D.

CHAP

Buy Now
Questions 18

You have a remote FlexCache storage device that is running on ONTAP Select 9.8 software. The cache origin volume Is on an FAS8700 that is running ONTAP 9.8 software. The WAN connection dropped, and the FlexCache volume is in disconnected mode.

In this scenario, which LIFs would you ping to troubleshoot the disconnect?

Options:

A.

management

B.

Intercluster

C.

data

D.

cluster

Buy Now
Questions 19

Exhibit

NS0-162 Question 19

You have Installed a new ONTAP 9.8 cluster and want to move the e0e and e0c ports into a new broadcast domain. Referring to the exhibit, which action satisfies this requirement?

Options:

A.

Use the irrDadcast-domain create command

B.

Use the broadcast-domain split command.

C.

Use ONTAP System Manager to create a new broadcast domain.

D.

Use the broadcast-domainmerge command.

Buy Now
Questions 20

Exhibit.

NS0-162 Question 20

You have a NetApp AFF A400 HA pair with Fabric Pool enabled on all data using the snapshot-only policy. Users are reporting slow restores when they recover files with the Windows Previous Versions tab.

Referring to the exhibit, what is the highest latency seen on restore?

Options:

A.

10500

B.

10021

C.

9591

D.

7889

Buy Now
Questions 21

Exhibit.

NS0-162 Question 21

You are adding a NetApp AFF A400 system to an existing 4-node cluster and want to know which ports you would use to expand your cluster.

Referring to the exhibit, which tool would you use to accomplish this task?

Options:

A.

Active 1Q Unified Manager

B.

NetApp Interoperability Matrix (IMT)

C.

Active IQ Conflg Advisor

D.

NetApp Hardware Universe (HWU)

Buy Now
Questions 22

Exhibit

NS0-162 Question 22

Referring to the exhibit, what is the maximum possible IOPS for the VOL_A volume?

Options:

A.

1000 IOPS

B.

500 IOPS

C.

2000 IOPS

D.

100 IOPS

Buy Now
Questions 23

Exhibit

NS0-162 Question 23

You have a 4-node ONTAP cluster and use FCP to access several LUNs. You perform a volume move to move a LUN (/vol/sql01_sysdb/lun) from node na01-01 to na01-03. After the move, you perform an HBA rescan from the host, but ALUA Is now seeing twice the number of paths to the LUN.

Referring to the exhibit, which action would solve the problem?

Options:

A.

Update the Selective LUN Map configuration for the LUN mapping.

B.

Change the MPIO policy on the host.

C.

Ensure that the fabric zoning is correct.

D.

Reboot the host.

Buy Now
Questions 24

Exhibit.

NS0-162 Question 24

You create a storage virtual machine (SVM) called SVM500 that is provisioned for iSCSI. After creating a LUN in the SVM and mapping it to an igroup, the attached VMware hosts are unable to mount the LUN.

Referring to the exhibit, what is the issue?

Options:

A.

The igroup contains the wrong protocol.

B.

The igroup contains multiple Initiators.

C.

The initiator is a member of igroups of different OS types.

D.

The igroup does not contain the appropriate initiators.

Buy Now
Questions 25

You want to add SSDs to existing HDD aggregates.

Which NetApp tool helps you to validate how many SSDs would Improve performance?

Options:

A.

OnCommand Workflow Automation

B.

Active IQ Unified Manager

C.

ONTAP System Manager

D.

Automated Workload Analyzer

Buy Now
Questions 26

SnapMirror Business Continuity (SM-BC) relies on a component to trigger an automatic unplanned failover (AUFO). In this scenario, what is this component?

Options:

A.

ONTAP Deploy

B.

Tiebreaker software

C.

ONTAP Mediator

D.

Cloud Manager

Buy Now
Exam Code: NS0-162
Exam Name: NetApp Certified Data Administrator (ONTAP)
Last Update: May 17, 2026
Questions: 89

PDF + Testing Engine

$64.99   $185.69

Testing Engine

$49.99   $142.83

PDF (Q&A)

$54.99   $157.11