Labour Day Sale Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 713PS592

NS0-520 NetApp Certified Implementation Engineer - SAN Specialist ONTAP Questions and Answers

Questions 4

You need to migrate boot LUNs from a third-party array onto a Netapp FAS8700. Which three actions are required to complete this task? (choose three)

Options:

A.

Reboot the third-party SAN to prepare for the LUN Import

B.

Verify third-party array support by using the Interoperability Matrix Tool (IMT)

C.

Convert every FC target port on each controller to an FC initiator port

D.

Convert a single FC port on each controller to an FC initiator port

E.

Create zoning between the third-party array to the FAS8700

Buy Now
Questions 5

You are planning on implementing a new SAN on AFF A400 controllers. The data set consists of unique 1 KB files that will be encrypted before being written to the SAN.

Options:

A.

Compaction

B.

compression

C.

Deduplication

D.

Autogrow

Buy Now
Questions 6

You upgraded your Linux hosts to SUSE Enterprise Linux 15. In this scenario, which two actions should you perform before you test asymmetric namespace access (ANA)? (Choose two)

Options:

A.

Verify if the NVMe service has started

B.

Verify if the LUNs and namespaces are in the same volume.

C.

Verify if the version of Netapp ONTAP software is 9.5 or later

D.

Verify if there is only one LIF in the SVM

Buy Now
Questions 7

An administrator is asked to provision a SAN environment in which host applications can monitor LUN space and performance space reclamation.

Which LUN type would satisfy these requirements?

Options:

A.

SCSI thick provisioned LUN

B.

SCSI thin provisioned LUN

C.

NetApp thin provisioned volume

D.

NetApp thick provisioned volume

Buy Now
Questions 8

You want to perform online data migration using Foreign LUN Import. In this scenario, which two conditions are required to support this task? (choose two)

Options:

A.

ISCSI protocol LIFs must be added to the data SVM

B.

ISCSI targets must be added to the ONTAP ISCSI initiator

C.

FCP protocol LIFs must be added to the data SVM

D.

FCP initiator ports must be available

Buy Now
Questions 9

Your customer asks you how to connect a host for SAN access to the newly installed AFF A400 system. In this scenario, which two statements are correct? (choose two)

Options:

A.

Direct Connection to the nodes from the hosts with ISCSI is supported

B.

Direct Connection to the nodes from the hosts with ISCSI is not supported

C.

Direct Connection to the nodes from the hosts with FC is not supported

D.

Direct Connection to the nodes from the hosts with FC is supported

Buy Now
Questions 10

During maintenance of an AFF A250 node, you want to move the SAN LIFs that are members of a port set. In this scenario, which two statements are true? (choose two)

Options:

A.

You must disable SLM for the node that hosts the LIF

B.

You need to disable the zoning of the LIF WWPN

C.

The LIF must be removed from the port set

D.

You must take the SAN LIF offline

Buy Now
Questions 11

You are a system administrator and responsible for a Netapp AFF A800 2-node ONTAP 9.8 cluster that is used only for SAN. Your SAN uses FC and FCoE on the same Cisco switches. You want to add

NVMe from the ONTAP controller to the same Cisco fabric. Which two statements are correct in this scenario? (choose two)

Options:

A.

The same SVM can serve both the FC and the FCoE protocols

B.

The same SVM cannot serve both the FC and the NVMe protocols

C.

FCoE and NVMe can share the same physical port

D.

FC and NVMe can share the same 32 GB physical port

Buy Now
Questions 12

You have a thin-provisioned LUN that was created by using the lun create -vserver vs1 - path /vol/vol1/lun1 -size 500G -ostype windows 2008 -space-reserve disabled -space-allocation disabled command. You verify that your Windows 2016 host reports 200 GB free on lun1. However, lun1 shows 0 bytes free on the storage cluster.

What should you do to solve this problem?

Options:

A.

Change the LUN -space-allocation parameter to enabled.

B.

Change the LUN -ostype parameter to windows_gpt.

C.

Change the LUN -space-reserve parameter to enabled.

D.

Rescan the LUN disk in your Windows host so that it will notify NetApp about the free space.

Buy Now
Questions 13

You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned by node01.

In this scenario, what would be an appropriate test for LUN mobility?

Options:

A.

Move the LUN to node02.

B.

Mirror the LUN to another node in your cluster.

C.

Physically disconnect the SAN ports, and verify if the SAN data LIFs automatically move to other hosts.

D.

Copy the LUN to another node and create a new LUN map.

Buy Now
Questions 14

An administrator needs to determine the maximum volume size that is supported per operating system.

Which resource has this information?

Options:

A.

Config Advisor

B.

OneCollect

C.

Interoperability Matrix Tool (IMT)

D.

Hardware Universe (HWU)

Buy Now
Questions 15

After the addition of extra DS224C disk shelves, you notice that the output of the system node run -node node_1 sysconfig command shows Mixed-path. You need to investigate why the additional shelves are providing this error.

In this scenario, which two tools would help diagnose this issue? (Choose two.)

Options:

A.

Config Advisor

B.

Active IQ

C.

Hardware Universe (HWU)

D.

Interoperability Matrix Tool (IMT)

Buy Now
Questions 16

As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is configured with the space guarantee set to volume and the LUN reservation is disabled. You want to free up space in the volume without increasing its size.

Which action would accomplish this task?

Options:

A.

Increase the size of the LUN.

B.

Increase the Snapshot Reserve.

C.

Increase the aggregate size.

D.

Use deduplication.

Buy Now
Questions 17

NS0-520 Question 17

Referring to the exhibit, what happens when you change the type for port 1a from target to initiator?

Options:

A.

The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect.

B.

You receive an error message that you must take ports 1a and 1b offline before you can change the type.

C.

B. You receive an error message that you must take the port 1a offline before you can change the type.

D.

The port type for 1a and 1b changes to initiator, and you must reboot the controller for the changes to take effect.

Buy Now
Questions 18

What is a SAN best practice when initially configuring a Linux FC boot LUN?

Options:

A.

Install the Host Utilities in the guest Linux OS.

B.

Map the WWPN of the target.

C.

Disable the HBA port with the host’s BIOS.

D.

Configure multipath to the LUN.

Buy Now
Questions 19

You are provisioning storage to an ESX host that uses iSCSI.

According to NetApp best practice, which three actions accomplish this task? (Choose three.)

Options:

A.

Enable the iSCSI service.

B.

Bind the iSCSI ports to the software iSCSI adapter.

C.

Install Virtual Storage Console (VSC) for VMware.

D.

Enable BGP on the switch.

E.

Configure MTU 1500 on the switch.

Buy Now
Questions 20

A customer is required to encrypt iSCSI traffic across their public network.

In this scenario, which method will accomplish this task?

Options:

A.

dot1q

B.

IPsec

C.

NVMe

D.

CHAP

Buy Now
Questions 21

NS0-520 Question 21

A customer needs to change ports 0e and 0f on AFF_1 to support FC.

Referring to the exhibit, which three steps are required to accomplish this task? (Choose three.)

Options:

A.

Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type target command.

B.

Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type initiator command.

C.

Restart the FC service.

D.

Take ports 0e and 0f offline.

E.

Reboot the node.

Buy Now
Questions 22

NS0-520 Question 22

Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.)

Options:

A.

deduplication

B.

compaction

C.

compression

D.

thin provisioning

Buy Now
Questions 23

NS0-520 Question 23

An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The hosts are not configured to connect to any other SVM.

Which action should be performed to restore multi-path connectivity to the LUNs in this scenario?

Options:

A.

Create LIFs on SVM "C" for host connectivity.

B.

Move the LUN to a different volume within SVM "C".

C.

Move the LUN to SVM "E" to restore connectivity.

D.

Move the LUN to SVM "A" to restore connectivity.

Buy Now
Questions 24

Which row of items should you look up in the IMT (Interoperability Matrix Tool) when designing a NetApp Storage Solution for a customer?

Options:

A.

Host OS & patches, FC WWPN, Volume Manager, File System version

B.

Host OS, iSCSI IQN, Volume Manager, Clustering

C.

Host OS & patches, HBA driver, Volume Manager, File System, Clustering

D.

Host OS, HBA driver, Host Memory & CPU Speed, File System, Clustering

Buy Now
Questions 25

Exhibit.

NS0-520 Question 25

Referring to the exhibit, what is the total number of target LUNs that are being accessed?

Options:

A.

4

B.

1

C.

2

D.

8

Buy Now
Questions 26

You have a 4-node FAS8200 A300 cluster that are using ONTAP 9.3 default settings. For faster performance, you move a volume with LUNs from a node on the FAS8200 to a node on the AFF A300. You determine that your SAN host is still using all active/optimized FC paths to the FAS8300 HA pair.

What do you need to troubleshoot to move all active/optimized FC paths to the AFF A300 HA pair?

Options:

A.

reporting nodes list

B.

host MPIO and ALUA

C.

LUN mapping

D.

igroup WWPNs

Buy Now
Questions 27

Exhibit.

NS0-520 Question 27

You are asked to change the iSCSl Target Node Name of an SVM named SVM1 that is serving data.

Referring to the exhibit, which two statements are correct? (Choose two.)

Options:

A.

Reconnect all the lUNs alter renaming the target node.

B.

Disable Selective LUN Mapping (SIM) and create port sets.

C.

Unmap and re-map the LUNs.

D.

Stop and start the iSCSI service.

Buy Now
Questions 28

When planning out a new FC SAN implementation for a AFF cluster, which two variables should be considered for a highly-available, resilient solution? (Choose two.)

Options:

A.

Length of LC/LC optic cables

B.

Multiple disk shelves

C.

Multiple PDUs connected to separate circuits

D.

Data-fabric zones using multiple switches

Buy Now
Questions 29

Exhibit.

NS0-520 Question 29

The exhibit shows the Inn show command output for the oradata oraFinProd_l LUN.

Which two statements ate correct about the LUN'? (Choose two.)

Options:

A.

The LUN Is thick provisioned.

B.

The LUN supports SCSI Tin unmap.

C.

The LUN type is Windows.

D.

The LUN is thin provisioned.

Buy Now
Questions 30

Which two scenarios in deploying ONTAP Cloud are supported by the Cloud Manager tool? (Choose two.)

Options:

A.

ONTAP Cloud deployed as an HA pair on IBM Cloud

B.

ONTAP Cloud deployed as an HA pair on VMware

C.

ONTAP Cloud deployed as a single instance on Microsoft Azure

D.

ONTAP Cloud deployed as an HA pair on Amazon Web Services

Buy Now
Questions 31

When does Fractional Reservation reserve space from the volume?

Options:

A.

Volume Creation

B.

LUN Creation

C.

LUN SnapMirror

D.

Volume Snapshot

Buy Now
Questions 32

Exhibit.

NS0-520 Question 32

A customer has an AFF A200 with a LUN residing in a volume by Node 4. The default Selection Mapping settings are effect. During a planned takeover cluster test, Node 3 performs a take over of Node 4.

Referring to the exhibit, what is the expected number of paths seen from the host?

Options:

A.

6

B.

8

C.

4

D.

2

Buy Now
Questions 33

What does the space allocation argument in a lun create command do?

Options:

A.

It thick provisions the LUN.

B.

It only disables space reclamation (or the LUN.

C.

It thin provisions the LUN,

D.

It enables or disables space reclamation for the LUN

Buy Now
Questions 34

A company wants to use jumbo frames to improve performance with their iSCSI network. When setting up the Ethernet switches for jumbo frames, which three components need to be configured? (Choose three.)

Options:

A.

Ethernet port on Management Console

B.

Ethernet port on RLM

C.

Ethernet port on host system

D.

Ethernet port on storage device

E.

Ethernet port on FC switch

F.

Ethernet switch ports being used

Buy Now
Questions 35

Which commands allow you to enable NetApp deduplication and verify space savings?

Options:

A.

sis on , sis start , df s

B.

asis on , asis start , df s

C.

sis on , sis start , df r

D.

sis on, sis start, df p

Buy Now
Exam Code: NS0-520
Exam Name: NetApp Certified Implementation Engineer - SAN Specialist ONTAP
Last Update: Apr 23, 2024
Questions: 234

PDF + Testing Engine

$66.4  $165.99

Testing Engine

$46  $114.99
buy now NS0-520 testing engine

PDF (Q&A)

$42  $104.99
buy now NS0-520 pdf