Month End Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: chrismas

Free Practice Questions for the Netapp NCIE SAN ONTAP NS0-522 Exam (2026 Updated)

At Marks4sure, we are dedicated to providing IT professionals with the most accurate and reliable preparation materials for the Netapp NS0-522 exam. To support your certification journey, we have made a selection of our premium 2026 NCIE SAN ONTAP practice questions and answers available completely free. You can take this practice test as many times as you need. Every question includes a detailed, expertly verified explanation to ensure you fully grasp the core security concepts before test day.

Questions 4

A customer has recently installed a new NetApp AFF system and Cisco Nexus 9000 Series switches for their SAN workload. The administrator is tasked with configuring interface groups for port-based load balancing.

Which two commands are required? (Choose two.)

Options:

A.

network port ifgrp create -distr-func port in NetApp ONTAP software

B.

port-channel load-balance src-dst l4port on the switch

C.

channel-group mode passive on the switch

D.

network port modify -flowcontrol-admin false in NetApp ONTAP software

Buy Now
Questions 5

During an iSCSI deployment, the customer requests a change of front-end network connections on the NetApp ONTAP cluster from twinax cables to fiber-optic cables.

Which two NetApp tools would an administrator use to verify the supported port speeds and transceivers? (Choose two.)

Options:

A.

Hardware Universe to determine supported transceivers

B.

Interoperability Matrix Tool to determine supported transceivers

C.

Hardware Universe to determine supported port speeds

D.

Interoperability Matrix Tool to determine supported port speeds

Buy Now
Questions 6

What is the maximum size for a LUN in NetApp ONTAP 9.14.1 software?

Options:

A.

16TiB

B.

64TiB

C.

128TiB

D.

300TiB

Buy Now
Questions 7

An administrator creates a new volume and a LUN for an SAN-connected application that uses snapshots. The application has fast-growing data that is constantly being populated and deleted afterwards.

Which option can be set to manage the space automatically?

Options:

A.

Enable automatic resizing on the volume.

B.

Enable space reservation on the LUN.

C.

Disable volume snapshot autodelete.

D.

Unmap the LUN.

Buy Now
Questions 8

An administrator is deploying a new SAN workload that has a NetApp All SAN Array (ASA) cluster. The customer wants to reclaim space by tiering to Azure Blob storage.

According to NetApp best practices, which volume tiering policy should be applied?

Options:

A.

Snapshot-Only

B.

All

C.

None

D.

Auto

Buy Now
Questions 9

What configuration must be applied for NVMe/FC?

Options:

A.

Create multiple initiator zones and multiple target zones.

B.

Configure igroup and IQN mapping.

C.

Enable NPV on all fabric switches.

D.

Enable NPIV on all fabric switches.

Buy Now
Questions 10

What connectivity Is required between NetApp ONTAP clusters in order to configure SnapMirror active sync across two data centers for FC?

Options:

A.

Cedicated FC switches and ISL

B.

Shared FC switches

C.

Cluster peering

D.

Dedicated IP switches and ISL

Buy Now
Questions 11

A customer has data in a LUN on an existing third-party SAN storage system that will be migrated to a new NetApp AFF A400 all-flash MetroCluster system. The host connected to the LUN is a Windows Server 2019 system.

In this scenario, which two methods are supported? (Choose two.)

Options:

A.

SnapMirror Business Continuity

B.

Foreign LUN Import in online mode

C.

Foreign LUN Import in offline mode

D.

Client-side copy of the data

Buy Now
Questions 12

Where is the zoning configuration stored in an FC SAN environment?

Options:

A.

The end hosts

B.

The FC adapters

C.

The storage system

D.

The FC switches

Buy Now
Questions 13

A SAN administrator has a new NetApp ONTAP cluster that is configured with iSCSI LUNs. The iSCSI LIFs are configured on interface groups with a 1500 MTU. The server and network administrators have a maintenance window scheduled to modify the server NIC and iSCSI switch VLANs to use jumbo frames.

Based on this scenario, which command enables jumbo frames?

Options:

A.

network port modify

B.

network interface modify

C.

broadcast-domain modify

D.

network subnet modify

Buy Now
Questions 14

Which feature enables simultaneous snapshots of multiple LUNs In different volumes?

Options:

A.

Single File SnapRestore

B.

Failover groups

C.

Consistency groups

D.

SyncMirror

Buy Now
Questions 15

A customer Is setting up a four-node NetApp AFF cluster for use with NVMe/TCP and wants to use automatic host discovery.

Which protocol is used for the discovery of controllers?

Options:

A.

TFTP

B.

mDNS

C.

LLDP

D.

PXE

Buy Now
Questions 16

A storage engineer is required to provide NetApp site design documentation to show that the NetApp ONTAP SAN solution was delivered as intended.

Which NetApp tool can the storage engineer use to automate the creation of a difference report?

Options:

A.

NetAppDocs

B.

Active IQ OneCollect

C.

Active IQ Config Advisor

D.

Harvest

Buy Now
Questions 17

A customer has a new eight-node NetApp AFF cluster that will serve NVMe/TCP namespaces to clients. Bidirectional in-band authentication is required between all NVMe hosts and the AFF cluster.

Which NetApp ONTAP feature must be configured to meet the requirement?

Options:

A.

DH-HMAC-CHAP

B.

SAML IdP

C.

Kerberos 5p

D.

Active Directory domain-tunnel

Buy Now
Questions 18

Which two NetApp features enable an administrator to limit the number of paths that a host sees to a LUN? (Choose two.)

Options:

A.

ALUA

B.

Portsets

C.

igroup

D.

Selective LUN Mapping

Buy Now
Questions 19

When using SnapMirror active sync between two clusters, which NetApp service orchestrates failover in case the primary storage system fails?

Options:

A.

Active IQ

B.

TieBreaker

C.

ONTAP Mediator

D.

SANtricity

Buy Now
Questions 20

What are two benefits of implementing VLANs for NVMe/TCP configurations? (Choose two.)

Options:

A.

Increased resiliency

B.

Reduced number of broadcast domains

C.

Increased security

D.

Reduced number of IPspaces

Buy Now
Questions 21

A customer has just purchased new FC adapters to use in their NetApp ONTAP nodes.

Where can the customer verify which slots the cards should be installed in?

Options:

A.

SAN Administration Guide

B.

Interoperability Matrix Tool

C.

NetAppDocs tool

D.

Hardware Universe

Buy Now
Questions 22

After deleting a LUN, an administrator notices that the space does not show as available. What needs to be done to reclaim the space?

Options:

A.

UnmaptheLUN.

B.

Delete the volume snapshots.

C.

Purge the recovery queue.

D.

Perform space reclamation.

Buy Now
Questions 23

A customer is using a new two-node NetApp All SAN Array (ASA) configuration with SnapMirror active sync. To verify that everything is set up correctly, the customer is reviewing the number of paths on the ESXi hosts.

How many paths should the customer see?

Options:

A.

4 Active/Optimized, 4 Active/Unoptimized

B.

6 Active/Optimized, 2 Active/Unoptimized

C.

2 Active/Optimized, 6 Active/Unoptimized

D.

8 Active/Optimized, 0 Active/Unoptimized

Buy Now
Questions 24

Which two NetApp features provide synchronous data replication between two sites for SAN workloads with automatic failover in case of a site disaster? (Choose two.)

Options:

A.

SnapMirror active sync

B.

SnapMirror SVM

C.

SnapMirror Synchronous

D.

MetroCluster IP

Buy Now
Questions 25

An engineer Is implementing a data migration scenario for a customer who has multiple FC LUNs across multiple third-party SAN arrays. The engineer wants to use Foreign LUN Import (FLI) for the migration.

What is a requirement on the destination NetApp ONTAP cluster for FLI?

Options:

A.

A valid SnapMirror license

B.

At least one FC port in initiator mode

C.

A valid NetApp XCP license

D.

At least one FC port in target mode

Buy Now
Questions 26

A customer opens a support case for performance issues with an FC Oracle database after migrating from a NetApp AFF system to a NetApp All SAN Array (ASA) platform. Further investigation shows that the number of paths exceeds the recommendation for SAN deployment.

What are two ways to address this problem? (Choose two.)

Options:

A.

Use Selective LUN Mapping.

B.

Reconfigure the fabric switch zoning.

C.

Have the database team change their backup and recovery schedules for the database.

D.

Reconfigure the ALUA settings.

Buy Now
Questions 27

What Is a recommended setting for using the NetApp ONTAP LUN fractional reserve?

Options:

A.

LUN space reservation is disabled.

B.

Space allocation is set to enable.

C.

Space guarantee is set to volume.

D.

Volume Snapshot copy automatic deletion is disabled.

Buy Now
Questions 28

An administrator has a NetApp AFF cluster supporting an application with twelve LUNs allocated across four volumes. There is a requirement to configure a Snapshot copy of all LUNs simultaneously as a single unit.

Which NetApp ONTAP command should be used to configure this requirement?

Options:

A.

lun igroup create

B.

network port ifgrp create

C.

volume conversion start

D.

vserver consistency-group create

Buy Now
Questions 29

An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.

Which NetApp ONTAP command will show the status of this test?

Options:

A.

snapmirror failover show

B.

network interface failover-groups show

C.

storage failover hwassist show

D.

snapnirror config-replication status show

Buy Now
Questions 30

An administrator upgraded their NetApp ONTAP software from release 9.10.1 to 9.13.1 on a NetApp All SAN Array (ASA) cluster and is creating a new iSCSI SVM.

Which automatic feature can be used with iSCSI?

Options:

A.

LIF failover

B.

LUN mapping

C.

CHAP authentication

D.

igroup creation

Buy Now
Questions 31

Which NetApp ONTAP option enables automatic host-side space management for a LUN?

Options:

A.

space-allocation

B.

space-reserve

C.

resize

D.

alua

Buy Now
Questions 32

After a storage administrator creates a LUN using the CLI, the LUN does not appear on the corresponding host.

What should be done to correct this issue?

Options:

A.

Online the LUN.

B.

Map the LUN.

C.

Mount a volume.

D.

Assign an export policy.

Buy Now
Exam Code: NS0-522
Exam Name: NetApp Implementation Engineer - SAN ONTAP Exam
Last Update: Aug 24, 2026
Questions: 107

PDF + Testing Engine

$55.71   $185.69

Testing Engine

$42.85   $142.83

PDF (Q&A)

$47.13   $157.11